background image

4

1.  Attach grille.

  Fasten grille to heater with two (2) screws from parts bag.
2.  Check operation.
  Turn on power at service entrance. Turn thermostat to its 

highest setting and make sure heating element and blower 

come on. Then turn it to its lowest setting and make sure 

element and blower shut off.

COMPLETE THE INSTALLATION

Summary of Contents for 170F

Page 1: ...on s in accordance with all applicable codes and standards including fire rated construction codes and standards 4 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 5 This heater is hot when in use To avoid burns do not let bare skin touch hot surfaces Keep combustible materials such as furniture pillows bedding papers clothes etc and curtains...

Page 2: ...OUSING WITH RETAINING SCREW HERE Place element end of heater assembly behind the tabs on the left side of housing Pivot the assembly in and fasten with retaining screw from parts bag Plug wiring harness into receptacle 3 Provide desired control The heater finish assembly has no adjustable thermostat control If a wall mounted control has been pre wired nothing else need be done If a built in thermo...

Page 3: ...120 VAC to 240 VAC Conversion 1 Disconnect ONE of the black wires with an insulated terminal from the motor 2 Disconnect the two 2 white wires with insulated terminals from each other Do not remove wire from beneath plastic wire tie 3 Connect black wire to white wire NOTE When heater is converted from 120 VAC to 240 VAC half wattage conversion is not possible BLACK WIRES connected to motor BLACK W...

Page 4: ...s from parts bag 2 Check operation Turn on power at service entrance Turn thermostat to its highest setting and make sure heating element and blower come on Then turn it to its lowest setting and make sure element and blower shut off COMPLETE THE INSTALLATION ...

Page 5: ...5 OPERATION Before using heater make sure heater has been properly installed according to installation steps beginning with the PLANNING section on page 1 ...

Page 6: ...stat is turned to its highest setting Turn power off at service entrance Remove knob and grille and press button marked RESET LUBRICATION The heater is permanently lubricated and never needs oiling or disassembly CLEANING Clean heater once a month as follows 1 Turn off power at service panel 2 Make sure heating element is cool 3 Use a soft brush attachment to gently vacuum grille open ings or wipe...

Page 7: ...imited Warranty Remedy During the applicable limited warranty period the Company will at its option provide replacement parts for or repair or replace without charge any Product or part thereof to the extent the Company finds it to be covered by and in breach of this limited warranty under normal use and service The Company will ship the repaired or replaced Product or replacement parts to you at ...

Page 8: ...replacement parts by part number NOT key number KEY PART NO NUMBER DESCRIPTION 1 97008681 Housing 2 98003036 Mounting Bracket 2 Required 3 99260512 8 18 Sheet Metal Nut 2 Required 4 99390015 Grounding Clip 5 97005422 Receptacle Assembly 6 98006975 Wiring Cover 7 99020130 Blower Wheel 8 99080248 Motor Models 170F and 174F 9 99270735 Tab Adapter 10 99030194 Thermal Overload 11 99271091 Guard 12 9800...