![Broadway Limited Paragon 4 Technical Reference Manual Download Page 194](http://html1.mh-extra.com/html/broadway-limited/paragon-4/paragon-4_technical-reference-manual_2815871194.webp)
194
CONTROL CVs
CV228
DCC Startup Timer
Description
This Value Contains the DCC Startup Timer
Values
0-255
Initial Value
1
Related CVs
Bit 7
Bit 0
0 0 0 0 0 0 0 1
On power up, the decoder will wait this much time in seconds to
detect the DCC system. If this value is too low, DC mode will start
the system resulting in strange behavior. The initial value is 1 second.