53-1004106-15 Installation Guide
Brocade
®
X6-4 Director Hardware Installation Guide
•
SanDisk 32 CZ48 USB 3.0 Flash Drive (SDCZ48-032G-UAM46)
•
SanDisk 16 CZ48 USB 3.0 Flash Drive (SDCZ48-016G-UAM46)
•
Kingston 32GB DataTraveler 100 G3 USB 3.0 Flash Drive (DT100G3/32GB)
•
Kingston 32GB DataTraveler G4 USB 3.0 Flash Drive (DTIG4/32GB)
•
PNY Attache 3.0 4 USB 32GB Flash Drive
•
PNY Attache 3.0 4 USB 16GB Flash Drive
These drives are not orderable from Broadcom but are widely available and can be purchased from other
suppliers.
1. Log on to the device using one of the following methods:
•
A serial console connection to the active CP blade. The active CP is indicated by an illuminated blue LED on the
blade front panel.
•
A telnet session using the chassis management IP address.
Log on to the device using
admin
as your password. If you have not changed the default password, use
password
.
2. Back up the device configuration using the
configUpload
command.
Follow the prompts to upload the configuration to an external host using the file transfer protocol (FTP), secure copy
protocol (SCP), or secure FTP (SFTP), or save the configuration to the local file system on device or attached USB
device.
switch:admin> configupload
Protocol (scp, ftp, sftp, local) [ftp]:
Server Name or IP Address [host]: 192.0.2.0
User Name [user]: anonymous
Path/Filename [(home dir)/config.txt]: dumps/supportsaves/fos9k/folder/d239
Section (all|chassis|FID# [all]):
configUpload complete: All selected config parameters are uploaded
3. Back up the virtual fabric configuration using the
configUpload -vf
command.
For more information on using the
configUpload
and
configUpload -vf
commands, refer to the
Brocade Fabric
OS Command Reference Manual
.
4. Enter the following commands for additional configuration information that you can save to files:
•
configShow
•
ipaddrShow
•
license --show
for Fabric OS 9.0 and higher, or
licenseShow
for Fabric OS versions earlier than 9.0
•
switchShow
Powering Down the Chassis
Perform the following steps to power down the chassis.
1. Shut down the chassis using the
sysShutdown
command.
switch::admin> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y
HA is disabled
53-1004106-15
66