Power-Up Options
Broadcom
®
March 28, 2014 • MMP920737TAG03-HWUM100-R
Page 11
BCM920737TAG-03 WICED Smart Tag Hardware User Manual
Power-Up Options
VDDIO can be sourced from three options:
•
Coin cell unregulated
•
Coin cell regulated
•
USB regulated
These options are set using SW2 and SW3 (see
. The default regulator
output is 1.8V.
To adjust the regulator output, feedback components can be adjusted as shown in
.
UART Boot-Up
The following procedure describes how to power up the tag board with the UART interface enabled.
1. SW2 and SW3 should be placed in any desired power configuration, as shown in
.
2. SW4 should be in HCI mode by placing all eight switches in the ON position.
3. Plug in the USB cable to connector J6. The Smart Tag will display in the Windows Device Manager as two
COM ports named USB Serial Port.
The evaluation board can now accept HCI commands or download firmware through the UART interface.
Table 3: Switch Settings for Power
Switch
Coin Cell Unregulated
Coin Cell Regulated
USB Regulated
SW2
1-2 (VUSB)
2-3 (VCOIN)
1-2 (VUSB)
SW3
2-3 (VCOIN)
1-2 (VREG)
1-2 (VREG)
Table 4: Voltage Regulator Output
VOUT
Component Values
3.3V
RFB1=470 k
Ω
, RFB2=150 k
Ω
, C22=100 pF
3.0V
RFB1=330 k
Ω
, RFB2=120 k
Ω
, C22=150 pF
1.8V
RFB1=300 k
Ω
, RFB2=240 k
Ω
, C22=150 pF
Note: If the device driver does not load correctly, the FTS2232H driver must be downloaded from the
FTDI website (see
http://www.ftdichip.com/Drivers/VCP.htm
).
Confidential