Broadcom
ACPL-352J-EB1200-RM100
25
ACPL-352J
Reference Manual
Infineon EconoPIM™ 3 IGBT Module EB1200-352J Evaluation Board
6.2 Typical Switching Waveforms
Switching waveforms during hard switching of the semiconductors are measured with an oscilloscope using the standard
double-pulse test procedure.
shows the turn-on switching transient, while in
, the turn-off switching
transient is depicted.
Figure 18: Oscilloscope Screenshot of Turn-On Transient, V
dc
= 600V, I
c
= 75A, CH1 (Yellow) V
ce
, CH3 (Blue) V
ge
, CH4 (Green)
V
dc
, F6 (Red) I
c
Figure 19: Oscilloscope Screenshot of Turn-Off Transient, V
dc
= 600V, I
c
= 75A, CH1 (Yellow) V
ce
, CH3 (Blue) V
ge
, CH4 (Green)
V
dc
, F6 (Red) I
c
6.3 Typical DESAT Protection Performance
The functioning of the DESAT protection is obtained by performing the direct short circuit on one of the bridge legs.
shows the results of this measurement.