In order to change the AC operating voltage it is necessary to change the switch inside the 

transmitter on the front of the power supply.  Sliding this switch right or left makes the 
selection for 110 or 220 VAC operation.  To access the power supply switch you will need 

to remove the top cover of the MT100 or the switch may also be accessed through the 

transmitter front panel by removing the four (4) corner screws on the front of the OME-1T 
stereo exciter then sliding it forward out of the way.  Look into the slot where the exciter 

was mounted using a battery operated light and locate the power supply selector switch 

(approximately 9 to 10 inches from the front panel) and make the proper selection.  

Replace the OME-1T or the transmitter top cover and replace all screws and hardware 
unless a change of operating frequency is necessary before operating the transmitter. 

 

Frequency Of Operation Change

 

The MT100 transmitter operating frequency at time of shipment from the factory may not 

be set for your authorized frequency.  In order to change the frequency of operation, 
locate, the OME-1T exciter section of this manual and review the information on page 4 of 

4.  After review the frequency setting examples in this section, substitute your values for 

the switch settings through the OME-1T chassis top.   You should make sure that the 
transmitter is unplugged and that no power present. 

 
To access the frequency change selector switches may be necessary to remove the four 

(4) screws on the front of the OME-1T and slide it forward far enough to allow a small 
screw driver blade to adjust the three (3) rotary frequency selector switches. 

 

Output Power Setting 

Please refer to the earlier section entitled RF Power Control in section 3.4 of this manual. 

 

Other Exciter Settings 

Please refer to the OME-1T exciter section of this manual, page 4 of 4, for jumper settings 
for left and right channel preemphasis selection (75 microseconds un-preemphasized, or 

50 microseconds), left and right input sensitivity selection (6..9dBm, 3..6dBm or 0..3dBm), 

modulation limiter selection (On or Off), and input selection (Mono, Multiplex Internal, or 
Multiplex External).  This page of the manual shows the various positions for the jumpers 

and their location on the OME-1T printed circuit board. 

Summary of Contents for MT100-E

Page 1: ...RFCAST MT100 Rev 2 06 12 04 1 16 OWNERS MANUAL Model MT100 E U 100 WATT FM STEREO TRANSMITTER...

Page 2: ...er to the section entitled RF Power Control in section 3 4 of this manual Notice 4 The factory settings of this manual for such this as Input Selection preemphasis and input sensitivity may not be cor...

Page 3: ...OULD A LARGER MORE VIEWABLE VERSION OF ANY DIAGRAM BE REQUIRED NOTIFY RICHARDSON ELECTRONICS LTD TO CALL OUR TECHNICAL SUPPORT CENTER OR FOR OTHER CUSTOMER SERVICE ISSUES AT RICHARDSON ELECTRONICS IN...

Page 4: ...t perform a visual inspection of the item s to determine if any damage occurred during shipment Be sure to retain all the shipping materials crates and boxes or cartons until such time that it has bee...

Page 5: ...e to perform associated tasks All local codes for building safety fire or related standards must be observed Consult local authorities for the standards for the area or region where the equipment will...

Page 6: ...e 9 3 3 FM Stereo Exciter page 9 3 4 MT100 RF Control Circuit page 9 3 5 MT100 RF Amplifier page 10 3 6 Low Pass Filter and Directional Coupler page 11 4 0 MT100 Technical Specifications page 12 5 0 S...

Page 7: ...rd Layout 17 0 MT100 Logic Control Board Layout 18 0 Logic Control Board MT100 Schematic 19 0 MT100 Low Pass Filter Layout 20 0 MT100 GR00175 250W Low Pass Filter Schematic 21 0 100W Directional Coupl...

Page 8: ...ne RF out LOW PASS FILTER and DIRECTIONAL COUPLER RF AMPLIFIER SECTION REFL1 REFL2 FWD RF PROTECTION TEMPERATURE RF CONTROL CIRCUIT RF Monitor AC DC CONVERTER DC DC CONVERTER 28 Vin 28 Vdc 15 Vdc FANs...

Page 9: ...this manual for more detailed specifications and for operational settings 3 4 MT100 RF Control Circuit The RF input circuit has 3 main functions 1 RF power control 2 RF protection 3 Measurement status...

Page 10: ...the rear panel contacts jumper are closed WARNING with enable off there is no RF out but all the internal circuits are powered stand by condition Remember to switch off the main on off switch on the...

Page 11: ...tion VCC 28V IDC Full Power 7 A typ Idq total per 2 sections 50 mA typ Frequency range FM 87 5 108 MHz Power Gain 17 dB typ Output Power 100 W The 2 way Combiner is a 2 way in quadrature structure and...

Page 12: ...00 cubic meters hour RF Characteristics Frequency Range 87 5 108 MHz 50Khz step synthesized Output Power 100 Watt nominal VSWR 1 8 1 RF Power Devices Technology MOSFET Off lock Attenuation 60 dBc RF O...

Page 13: ...8dBc Audio Filter rejection 19KHz to 100KHz 30 dB 19KHz suppression 46dB External MPX Input Input connectors BNC female front panel Input Impedance 10K Input level For 75KHz deviation 3 to 9 dBm 600 C...

Page 14: ...ation The input main voltage is set at the factory or it may be changed by the switch located on the AC DC converter A label on the transmitter chassis rear indicates the factory set AC voltage The no...

Page 15: ...rized frequency In order to change the frequency of operation locate the OME 1T exciter section of this manual and review the information on page 4 of 4 After review the frequency setting examples in...

Page 16: ...operating temperature is too high the temperature protection intervenes when the room temperature is 45 In this case the output power is reduced of about 6dB Fault red on if the transmitter has other...

Reviews: