background image

RFCAST – MT100.   Rev. 2:  06-12-04                       

12/16 

The directional coupler is a block composed by 2 directional couplers and a quarter wave 
delay line. Both ports of each directional coupler are used. Two of them detect the 
reflected power, one detects the FWD power and one is used as RF monitor. The function 

of the delay line is to have two reflected power signals detected at 90° of electrical angle.  
In this way, it is possible to have a quite constant reflected power level vs. the phase 
angle of that signal. The RF monitor is connected to the front panel (RF monitor port) to 
have +10 dB nominal signal. 

 

4.0   MT100 Technical Specifications 

 

Environmental 

Storage Temperature: 

-20/+65 

°

Operating Temperature: 

-5/+45 

°

Guarantee Performance Temperature: 

0/+45 

°

Relative Humidity (Non Condensing): 

< 90% 

Guarantee Performance Altitude: 

2000 m, (6560 ft) 

Cooling: 

> 100 cubic meters/hour 

 

RF Characteristics 

 
Frequency Range: 

87.5 – 108 MHz, 50Khz step, synthesized. 

Output Power: 

100 Watt nominal, (VSWR < 1.8:1). 

RF Power Devices Technology: 

MOSFET 

Off lock Attenuation: 

> 60 dBc 

RF Output connector: 

N Female 

RF Output Impedance: 

50 

 

RF Output monitor level: 

0 dBm nominal (BNC connector on the front panel) 

RF Spurious: 

< -95dBc @ +/-1MHz (Exceed .EBU/CCIR/FCC) 

Harmonic: < 

-90dBc 

Frequency stability: 

< 500 Hz / 6 months @ Center Frequency 

Inputs: 

Mono, Stereo, MPX, AUX, SCA/RDS 

Input Impedance: 

600

 or 5K

 unbalanced 

Modulation Type: 

F3E/F8E Direct FM at the carrier frequency 

Frequency deviation: 

+/-75KHz=100% 

Variation of sensitivity for 75 KHz 

Deviation: 

+/-1dB from 87.5 to 108 MHz 

AF Limiter: 

+1dB 

Center Frequency Shift: 

< +/-500Hz, (Due to +/-75KHz Mod) 

Stereo Operation: 

CCIR 450/S2 “Pilot Tone System” 

Asynchronous AM SNR: 
(REF=100% AM Mod, @400Hz, BW=30Hz 
to 20KHz, FM Mod OFF) 

- 56dB 

Synchronous AM SNR: 
(REF=100% AM Mod, @400Hz, BW=30Hz 
to 20KHz, FM Mod +/-75KHz @400Hz) 

-50dB 
 

 

 
 
Electrical 

 
Power Supply: 

96/130 or 200/268 V, Single Phase AC, 48 to 62Hz. 

Power Consumption: 

< 250 VA 

Summary of Contents for MT100-E

Page 1: ...RFCAST MT100 Rev 2 06 12 04 1 16 OWNERS MANUAL Model MT100 E U 100 WATT FM STEREO TRANSMITTER...

Page 2: ...er to the section entitled RF Power Control in section 3 4 of this manual Notice 4 The factory settings of this manual for such this as Input Selection preemphasis and input sensitivity may not be cor...

Page 3: ...OULD A LARGER MORE VIEWABLE VERSION OF ANY DIAGRAM BE REQUIRED NOTIFY RICHARDSON ELECTRONICS LTD TO CALL OUR TECHNICAL SUPPORT CENTER OR FOR OTHER CUSTOMER SERVICE ISSUES AT RICHARDSON ELECTRONICS IN...

Page 4: ...t perform a visual inspection of the item s to determine if any damage occurred during shipment Be sure to retain all the shipping materials crates and boxes or cartons until such time that it has bee...

Page 5: ...e to perform associated tasks All local codes for building safety fire or related standards must be observed Consult local authorities for the standards for the area or region where the equipment will...

Page 6: ...e 9 3 3 FM Stereo Exciter page 9 3 4 MT100 RF Control Circuit page 9 3 5 MT100 RF Amplifier page 10 3 6 Low Pass Filter and Directional Coupler page 11 4 0 MT100 Technical Specifications page 12 5 0 S...

Page 7: ...rd Layout 17 0 MT100 Logic Control Board Layout 18 0 Logic Control Board MT100 Schematic 19 0 MT100 Low Pass Filter Layout 20 0 MT100 GR00175 250W Low Pass Filter Schematic 21 0 100W Directional Coupl...

Page 8: ...ne RF out LOW PASS FILTER and DIRECTIONAL COUPLER RF AMPLIFIER SECTION REFL1 REFL2 FWD RF PROTECTION TEMPERATURE RF CONTROL CIRCUIT RF Monitor AC DC CONVERTER DC DC CONVERTER 28 Vin 28 Vdc 15 Vdc FANs...

Page 9: ...this manual for more detailed specifications and for operational settings 3 4 MT100 RF Control Circuit The RF input circuit has 3 main functions 1 RF power control 2 RF protection 3 Measurement status...

Page 10: ...the rear panel contacts jumper are closed WARNING with enable off there is no RF out but all the internal circuits are powered stand by condition Remember to switch off the main on off switch on the...

Page 11: ...tion VCC 28V IDC Full Power 7 A typ Idq total per 2 sections 50 mA typ Frequency range FM 87 5 108 MHz Power Gain 17 dB typ Output Power 100 W The 2 way Combiner is a 2 way in quadrature structure and...

Page 12: ...00 cubic meters hour RF Characteristics Frequency Range 87 5 108 MHz 50Khz step synthesized Output Power 100 Watt nominal VSWR 1 8 1 RF Power Devices Technology MOSFET Off lock Attenuation 60 dBc RF O...

Page 13: ...8dBc Audio Filter rejection 19KHz to 100KHz 30 dB 19KHz suppression 46dB External MPX Input Input connectors BNC female front panel Input Impedance 10K Input level For 75KHz deviation 3 to 9 dBm 600 C...

Page 14: ...ation The input main voltage is set at the factory or it may be changed by the switch located on the AC DC converter A label on the transmitter chassis rear indicates the factory set AC voltage The no...

Page 15: ...rized frequency In order to change the frequency of operation locate the OME 1T exciter section of this manual and review the information on page 4 of 4 After review the frequency setting examples in...

Page 16: ...operating temperature is too high the temperature protection intervenes when the room temperature is 45 In this case the output power is reduced of about 6dB Fault red on if the transmitter has other...

Reviews: