WVRC-4 Installation and Operation Manual
PROGRAMMING
Message
Address
Length (Sec)
Relay 1
51
5
Relay 2
52
5
Relay 3
53
5
Relay 4
54
5
Relay 5
55
5
Relay 6
56
5
Relay 7
57
5
Relay 8
58
5
Temperature
60
2.6
Degrees Celsius
61
2.6
Degrees Fahrenheit
62
2.6
Minus
63
2.6
Enabled
64
2.6
Disabled
65
2.6
Point
66
2.6
Temperature Alarm
67
2.6
“CONFIGURE” DIP Switch settings:
NOTE: The “UP” position is OFF
DIP 1 - Feature creep
DIP 2 - OFF = Voice Temperature in Fahrenheit, ON = Celsius.
DIP 3 - If OFF, description messages will be played when controlled via dial-up. If
ON, raise and lower description messages will not be played.
DIP 4 - OFF = Server control, ON = PC control via DB9.
DIP 5 - OFF = Normal operation, ON = DB9 RS-232 to web server.
DIP 6 - Feature creep
DIP 7 - Feature creep
DIP 8 - If OFF, input alarms are active. If ON, alarms will not respond.