Broadcast Tools Universal 4.1 MLR/Serial Installation And Operation Manual Download Page 4

e-mail: 

[email protected]   

voice: 

360.854.9559   

fax: 

866.783.1742

4

Universal 4.1 MLR Installation and Operation Manual

OVERVIEW

Product Overview

The Universal 4.1 MLR/Serial is a transparent four input, one output switcher/router
with mechanical latching relays designed to pass AES/EBU digital audio or stereo
analog audio signals. The Universal 4.1 MLR/Serial is perfect for all types of passive
signal switching via front panel button, USB/RS-232 serial, and contact
closures/logic remote control. The inputs and output feature stereo XLR and
St compatible RJ45’s connectors. Switching is accomplished via mechani-
cal latching gold contact relays, which means that the unit can route a signal in either
direction and will keep routing signal even after losing power. Due to the passive
nature of the switching, any input level and impedance can be used. Inputs may be
balanced or unbalanced, while output levels, impedance, distortion, noise and bal-
ancing will match that of the selected input.

Features/Benefits

• Front panel channel selection push buttons with active channel LED indicators.
• The “MUTE” function with LED indicator allows the user to turn off all audio

to the output.

• Front panel Enable switch with enabled LED indicator can be configured to pro-

vide a safety lock to the front panel selection push buttons.

• Signal switching via mechanical latching sealed relays utilizing 2-form-C bifur-

cated – crossbar silver alloy with gold overlay contacts.

• USB and RS-232 serial interfaces for connection to control PC.
• Five input GPI port (PIP triggers or remote control)
• Four normally open relay contact closure outputs for remote channel status.
• Stereo XLR and St RJ45’s connectors. The RJ45’s conforms to the

St wiring standard and passes “DC-LINK” power.

• Removable euro-block screw terminal connectors are used for remote control

connections. Necessary mating plugs are supplied.

• If power is lost, the last selected channel is passed to the output.
• Fully RFI proofed.
• Surge protected internal power supply, 9 VDC universal switching power supply

with domestic connector supplied. International connectors optional.

• Small 1-RU rack chassis.

Applications

Source switching; Studio selection and routing; Audio processing selection; Exciter
input selection; Remote broadcast input selection; STL source selection; PA switch-
ing; IFB selection; Satellite audio channel switching and console monitor input and
output selection.  

Inspection

Please examine your UNIVERSAL 4.1 MLR/SERIAL carefully for any damage that
may have been sustained during shipping. If any damage is present, please notify the
shipper immediately and retain the packaging for inspection by the shipper. The
package should contain the UNIVERSAL 4.1 MLR/SERIAL, a USB type A/B
cable, a modular cable with 9-pin “S9” female D-sub adapter, and a 9 VDC wall
transformer. Manuals may be downloaded from our web site.

WEBSITE:

Visit our web site for
product updates and
additional information.

Summary of Contents for Universal 4.1 MLR/Serial

Page 1: ...istered trademarks of Broadcast Tools Inc Copyright 1989 2017 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed without permission Visit www broadcas...

Page 2: ...ion 5 UPS standby power system 5 Installation Operation 5 Front Panel Controls 5 LED Indicators 5 Power Connector Pin outs 6 Audio Inputs and Outputs 7 Remote Control Inputs 8 Relay Outputs 8 Configur...

Page 3: ...t proper safety precautions have been taken before installing this device If you are unfamiliar with this type of equipment please contact a properly qualified engineer to handle the installation and...

Page 4: ...d relays utilizing 2 form C bifur cated crossbar silver alloy with gold overlay contacts USB and RS 232 serial interfaces for connection to control PC Five input GPI port PIP triggers or remote contro...

Page 5: ...and enable push buttons Each push button has an associated LED indicator When an input channel is selected its LED will light and the previously selected channel will turn off interlock Only one input...

Page 6: ...ct FTDI USB Serial Virtual COM port driver which will allow you to access the Universal 4 1 MLR Serial on a COM port If the switcher is being used for RS 232 serial operation the USB connection should...

Page 7: ...ng power Due to the passive nature of the switching any input level and impedance can be used Inputs may be balanced or unbalanced while output lev els impedance distortion noise and balancing will ma...

Page 8: ...Universal 4 1 MLR Serial and remain switched that way until a front panel source switch is pressed a different remote control input is activated Relay Outputs The Universal 4 1 MLR Serial has four nor...

Page 9: ...tion Mode SW9 4 Remote Control OFF PIP ON Remote control operation mode Pulse 1 IN to ground to select channel 1 pulse IN 2 to select channel 2 pulse IN 3 to select channel 3 pulse IN 4 to select inpu...

Page 10: ...e USB COM port the Universal 4 1 MLR Serial is assigned to at 9600 baud 8 N 1 flow control to NONE Emulation set to ANSI and local character echo enabled NOTE If the Universal 4 1 MLR Serial s FTDI US...

Page 11: ...nformation POLL Returns unit ID address in appropriate time slot uSL Seaudio status for all inputs SuLo x x x x CR LF uSPii Sends PIP status for input ii SuP ii x uSPA Sends PIP status for all inputs...

Page 12: ...u Operation Type 0mm to access the setup menu To select a menu function simply enter the letter on the left side of the menu and wait for the prompt Example Type the let ter S Response Enter Input Cha...

Page 13: ...le with 5 volts CMOS TTL logic open collector or contact closures to ground Status Front Panel LED Indicators Remote Four channel relay status output contacts 30 VDC 1 amp maximum CAUTION For safety n...

Page 14: ...NO OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO I...

Page 15: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 15 APPENDIX...

Page 16: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 16 APPENDIX...

Page 17: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 17 APPENDIX...

Reviews: