e-mail:
voice:
360.854.9559
fax:
866-783-1742
6
VAD-2 Installation and Operation Manual
PROGRAMMING
Dial Out Numbers/Messages
Keypad entry (Command code)
Dial out number (1)
11nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn
Example:
1113608549559
Dial out number (2)
12nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn
Example:
125551212
Dial out number (3)
13nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn
Example:
1315415551111
Dial out number (4)
14nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn
Example:
1417605551234
Pager Dial out (5)
15nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn
Example:
1518007597243***123456789#
Pager (DISPLAY) Data
16nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn
Example:
163605551212 (This may be the site phone
number where the VAD-2 is located)?
Security Code
21nnnnnnnn (Default 123)
Example:
212580
Access Code
22nnnnnnnn (Default 456)
Example:
22456
Lap, #Ring, Repeat 1, Repeat 2, Repeat 3, Silence Sensor delay timer
23LRPPPS, (program all six at once, single digits 1-8), except the silence sensor timer (0 to 9).
Example: 23324441.
This example would set the number of laps to 3,
the VAD-2 would pick up in 2 rings, repeat 4
times for inputs 1 thru 3 and a silence sensor
delay of 10 seconds.
Note:
Silence sensor time
delay settings: Factory default is (0) OFF, 1 =
10 sec, 2 = 30 sec, 3 = 60 sec, 4 = 1.5 min, 5 = 2
min, 6 = 2.5 min, 7 = 3 min, 8 = 4 min, 9 = 5 min.
Lap
refers to the number of attempts a call-out
is made to all numbers on a call-out list before
it gives up if no one acknowledges the alarm.
This is a global setting.
Ring
is the is the number of rings required before
the VAD-2 picks up. This is a global setting.
Repeat
is the number of times the alarm mes-
sage is repeated in a call-out. This is set for
each input.
WEBSITE:
Visit our web site for
product updates and