Broadcast Tools Streaming Sentinel 4 Installation And Operation Manual Download Page 20

e-mail: 

[email protected]   

voice: 

360.854.9559   

fax: 

866.783.1742

20

Streaming Sentinel 4 Installation and Operation Manual

WEB SETUP

“Email/Network Setup” Web Page – NTP Settings

NTP Enabled:

Enable for NTP network time sync. 
Default: Enabled

NTP (Time) Server Address: Enter the NTP address here.

Default: pool.ntp.org

NTP Port:

Port used to connect to NTP server. Default: 123

NTP Update Interval (Min): Interval between time updates. 

Default: 60

“Email/Network Setup” Web Page – Other Settings

Site ID:

This is the Site Identifier that is displayed on the web
and in email.

Monitor Refresh Time (Sec): Interval at which the Monitor page refreshes. Shorter 

times may increase network traffic.

Time Zone Offset from UTC: Sets the time zone used for the internal clock.

Default: -8

Enable Daylight Savings:

Adjusts the clock for daylight savings time.

Set Time:

The hour, minute, second, month, day and year boxes
can be used to set the time of the real time clock. The
time is only updated if you click “Save Time” and not
when you “Save Settings”.

Enable Event Logging: 

Event logging will generate an alarm, but it will not
send an email.  If the system is configured for Daily
Alarm emails, then that Daily Alarm email will con-
tain the event logging alarms as well as the alarms
configured on the I/O Setup page.

Login:

When someone logs into the unit, the username and
date/time will be logged.

Email: 

When an email is sent, the type of email and date/time
will be logged.

Reboot: 

When the device boots the date/time will be logged.

Alarms Cleared: 

When the Daily Logs or Normal Alarms are cleared,
the type of log cleared and date/time will be stored.
When Daily Logs are sent, the Daily Logs are also
cleared; this will cause an event log as well.

NOTE:

A cold-start trap will
be sent when the unit
boots up if the SNMP
Enable Traps are
enabled and trap mes-
sages will be sent when
a device enters or exits
an alarm condition,
depending on whether
or not alarms are
enabled.

WEBSITE:

Visit our web site for
product updates and
additional information.

Summary of Contents for Streaming Sentinel 4

Page 1: ...e registered trademarks of Broadcast Tools Inc Copyright 1989 2019 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed without permission Visit www bro...

Page 2: ...Controls 5 Balanced Analog Audio Output 5 Relay and Remote Control Connections 5 Telco Line Jack 5 LAN NET Jack 5 MicroSD Card Slot 5 Power 6 Web Setup Operation 7 Ethernet Quick Start Guide 7 Login P...

Page 3: ...NEL 4 Broadcast Tools Inc is unable to support NON Broadcast Tools software hardware or NON Broadcast Tools computer hardware software problems If you experience these problems please research your ha...

Page 4: ...ully RFI proofed Surge protected internal power supply PS 1515 universal switching 15VDC power supply with domestic connectors supplied International AC connectors optional Up to two units may be moun...

Page 5: ...M LVL Powered monitor level control allows adjustment of analog output volume when enabled with Fixed PM Switch HdPh LVL Headphone output level control adjacent to stereo headphone jack Defaults The D...

Page 6: ...d Slot MicroSD memory card slot Used for file storage and firmware updates Chassis Ground Chs Gnd For connection to the station site ground system Power Connect the supplied PS 1515 15 VDC switching p...

Page 7: ...liar with Ethernet enabled equipment it may be use ful to contact your IT department network administrator or network consultant for assistance Assigning an IP address already in use by another device...

Page 8: ...r web site for product updates and additional information Step 2 Double click on the icon labeled Network Connections The following menu will pop up Step 3 Right click on the icon labeled Local Area C...

Page 9: ...ouble click on Internet Protocol TCP IP to display properties Step 5 Before making any changes to the network settings write down the current settings or screen capture the page and print so that they...

Page 10: ...he product s power jack Verify that the front panel green POWER LED is ON and the left LINK LED above the NET Network RJ 45 connector is illuminated Open the product s login page by typing the followi...

Page 11: ...SITE Visit our web site for product updates and additional information Login Web Page The Login screen displays the Username and Password entry points as well as the date time and site ID You may view...

Page 12: ...s an explanation of each item on this page Site ID Identifies the unit and location Data Time Current date time from the Streaming Sentinel Queued Logs Displays the number of queued log entries schedu...

Page 13: ...trol 2 Monitor Control allows access to these pages About Monitor Control Show log Help and Logout 3 Monitor Only allows access to these pages About Monitor only Help and Logout Only users with Admin...

Page 14: ...ents and alarm voice message upload The Streams dropdown menu is used to choose between the 4 stream monitoring channels Label Name descriptor of stream to be monitored Log Device Enables email snapsh...

Page 15: ...he ping status Timeout This specifies how long to wait for a ping response from the ping address before timeout unreachable Monitor Interval The interval at which the Streaming Sentinel pings the ping...

Page 16: ...led dial out alarms you can enter up to four phone numbers to call out alarm messages to Label Name descriptor for phone number Phone Number Phone number you wish to receive alarm messages Formatted a...

Page 17: ...casttools com voice 360 854 9559 fax 866 783 1742 17 Streaming Sentinel 4 Installation and Operation Manual WEB SETUP WEBSITE Visit our web site for product updates and additional information Email Ne...

Page 18: ...SMTP Host ID Enter something here to identify the device Secured SMTP STARTTLS secure authentication is supported by most providers This must be enabled for many SMTP servers like Gmail Leave disabled...

Page 19: ...is selected then each alarm is queued and emailed as a digest every 24 hours Both can be used at the same time The number of queued alarms is displayed on the Monitor Control page Daily Alarm Email T...

Page 20: ...the time of the real time clock The time is only updated if you click Save Time and not when you Save Settings Enable Event Logging Event logging will generate an alarm but it will not send an email...

Page 21: ...Reload Defaults When you press the Reload Defaults button the device resets to factory default settings Clear Daily Logs When you press the Clear Daily Logs button the daily logs stored in memory wil...

Page 22: ...s the device or event Message Describes event alarm condition Date Displays the date that the event alarm was logged Time Displays the time that the event alarm was logged NOTE With the admin access l...

Page 23: ...1742 23 Streaming Sentinel 4 Installation and Operation Manual WEB SETUP WEBSITE Visit our web site for product updates and additional information About Web Page The About Web Page displays the produc...

Page 24: ...t sinks 6 VDC 100 mA max One SPDT dry contact relay output 30 VDC 1 Amp max CAUTION For safety never connect 120 Vac circuits to the unit Power Supply PS 1515 universal switching power supply with dom...

Page 25: ...es NO OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO...

Page 26: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Streaming Sentinel 4 Installation and Operation Manual 26 APPENDIX...

Page 27: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 27 APPENDIX...

Page 28: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 28 APPENDIX...

Page 29: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 29 APPENDIX...

Page 30: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 30 APPENDIX...

Reviews: