Streaming Sentinel 4 Installation and Operation Manual
WEB SETUP
“Email/Network Setup” Web Page – Email Logging Settings
Logging Email Address:
Email address for the “Logging” email recipient (may
be different from the 8 “Alarm” Recipient Addresses.
Logging emails and Daily emails are sent to this
address only.
Logging Email Snapshot Interval: The period in hours that a snapshot is taken of the
system. The logging email is not sent on this interval.
Logging Email Update Interval:
The period in hours that snapshots are emailed. This
email may contain multiple snapshots if the Snapshot
Interval is less than the Update Interval. Each snapshot
will be identified by the date and time.
“Email/Network Setup” Web Page – Email Alarm Settings
Email Alarms:
Choose Immediate and/or Daily. If Immediate is select-
ed, then an email will be sent out as soon as an alarm is
generated. If Daily is selected, then each alarm is
queued and emailed as a digest every 24 hours. Both
can be used at the same time. The number of queued
alarms is displayed on the Monitor/Control page.
Daily Alarm Email Time:
The time that queued alarms are sent. Queued alarms
are sent to the Logging Email Address only.
“Alarm” Recipient Address:
Email addresses for up to 8 addresses. These address-
es correlate to the 8 email addresses selectable on the
I/O Setup page.
“Email/Network Setup” Web Page – SNMP Manager Settings
SNMP Enable Traps:
When checked, SNMP trap messages will be sent.
When unchecked, no trap messages will be sent to the
manager.
SNMP Manager IP Address:
This is the IP address of the SNMP manager. The sys-
tem only accepts SNMP requests from this IP address,
and will send traps to this IP address only.
SNMP Manager Trap Port:
This is the port number that SNMP trap messages will
be sent to at the manager IP. Default port 161.
SNMP Read Community:
This is the community name used for Read-Only
access.
SNMP Write Community:
This is the community name used for Read-Write
access.