Configuration Jumper Setup
JP1: To enable the front panel “ENABLE” switch remove and stow the jumper
installed on the JP1 PCB header. Factory configuration: disabled.
NOTE: The enable push button must be held closed to operate any of the other
front panel push buttons and is not associated with any of the remote-control
functions.
Configuration Dip-switch Setup
Follow the tables below for SW11 dip-switch configuration options.
Note: To select an input at power-up with SW11-6 ON, hold down the push-
button for the desired input channel or mute until the front panel LED’s flash.
• Remote control operation mode: Pulse PIP1 to ground (DGND) to select channel
1, pulse PIP8 to select input 8 etc., pulse the Mute pin to turn off all channels.
• PIP mode: activity on any of the PIP inputs will generate a serial status string in
the PIP format. For use with automation software.
Note: After changing any dipswitch, please repower the unit.
Note: * Denotes factory setting.