Broadcast Tools SS 8.1 MLR Installation And Operation Manual Download Page 7

e-mail: 

[email protected]   

voice: 

360.854.9559   

fax: 

866.783.1742

7

SS 8.1 MLR/RJ Installation and Operation Manual

OPERATION

PIP (GPI)/Remote Control Inputs

The SS 8.1 MLR/RJ interfaces to external equipment through removable euro-block
screw terminals. The terminals accommodate wire sizes from 16 - 28 AWG solid or
stranded wire. Before installing a wire, remove the euro-block screw terminal plug
and turn each capture screw fully counterclockwise. Strip each conductor to a length
of 0.25” and insert the conductor fully into the terminal. Turn the capture screw fully
clockwise to secure the conductor.

The SS 8.1 MLR/RJ has eight status inputs that may be configured for PIP (“trig-
gers”) or remote-control operation and accept momentary contact closures (sus-
tained, if break before make); open collector or TTL/CMOS input logic levels.

The PIP/remote control operation mode is set by the SW11-7 dipswitch, when
SW11-7 is OFF the unit is in remote control mode and when SW11-7 in ON the unit
is in PIP mode. The PIP/remote control connections to the switcher are found on the
top rows of the connectors TB6 and TB7. Each channel may be selected by a
momentary contact to ground (DGND) located on the bottom TB7 connector. Each
channel is pulled high (5-volts) through a 22K resistor. For example, pulsing the
“MUTE” input to ground would turn off the output of the SS 8.1 MLR/RJ until a
front panel source switch is pressed, a different remote-control input is activated, the
unit is powered up and/or a serial command is received from a PC or other serial
device.

Pulsing the “STEP” input to ground will step the unit one source for each low to high
transition on this input. Automatic timed sequencing may be accomplished by hold-
ing the step input low. The unit will now step to each source at a user programma-
ble rate from 1 to 99 seconds (10 seconds by default). The last step channel is user
programmable and is set to 8 by default. This feature may be used to sequence
through multiple station air monitor signals for a program on-hold feed.  

The SS 8.1 MLR/RJ is also capable of being used for EAS audio insertion. This fea-
ture is enabled by setting the EAS controlled input channel via RS232 to the desired
audio input channel (see the Serial Operation section of this manual for more infor-
mation.) Once an input channel has been designated the SS 8.1 MLR/RJ will auto-
matically switch to that input for the duration of a sustained closure to ground on the
designated PIP/remote control input.  When released, the previous selected input
will be activated.

WEBSITE:

Visit our web site for
product updates and
additional information.

Summary of Contents for SS 8.1 MLR

Page 1: ...ed trademarks of Broadcast Tools Inc Copyright 1989 2021 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed without permission Visit www broadcasttool...

Page 2: ...ystem 5 Installation Operation 5 Input Mute and Enable Push Buttons 5 LED Indicators 5 Power 5 Chassis Ground 5 I O Connections 6 RJ45 Audio Inputs and Output 6 GPI PIP Remote Control Inputs 7 Open Co...

Page 3: ...of the SS 8 1 MLR RJ Broadcast Tools Inc is unable to support NON Broadcast Tools software hardware or NON Broadcast Tools computer hardware software problems If you experience these problems please r...

Page 4: ...ence sensor with front panel LED indicator SPDT SPST silence sensor alarm relay with adjustable alarm delay and restore duration May be disabled Eight input GPI port PIP triggers or Remote Control wit...

Page 5: ...ute respectively Each input push button has an associated LED indicator which will illuminate when the channel is selected When an input channel is selected the previous channel is des elected interlo...

Page 6: ...ch channel has a pair of resistors Removal information Channel 1 R6 R14 Channel 2 R7 R15 Channel 3 R8 R16 Channel 4 R9 R17 Channel 5 R10 R18 Channel 6 R11 RR19 Channel 7 R12 R20 Channel 8 R13 R21 If t...

Page 7: ...nector Each channel is pulled high 5 volts through a 22K resistor For example pulsing the MUTE input to ground would turn off the output of the SS 8 1 MLR RJ until a front panel source switch is press...

Page 8: ...the relays will close when silence is detected and stay closed until valid audio returns to the output RS 232 Serial Port RJ 11 Jack This RJ 11 jack is used to connect the SS 8 1 MLR RJ to a computer...

Page 9: ...switch Setup Follow the tables below for SW11 dip switch configuration options Note To select an input at power up with SW11 6 ON hold down the push button for the desired input channel or mute until...

Page 10: ...s for each unit using the configuration dipswitches zero is the factory default setting Never duplicate addresses Menu Operation To connect to the SS 8 1 MLR RJ over its serial interface start a seria...

Page 11: ...is silent uU Sends unit firmware version name version lf uY Display configuration uZx Echo character x to serial control port for debugging command strings uCEx Enable error and good responses if x Y...

Page 12: ...us outputs rated at 6 vdc 100ma each One SPDT and one SPST silence sense relay 1 amp 30 vdc maximum Interfacing Audio I O shielded RJ45 audio jacks Remote control 4 6 position pluggable screw terminal...

Page 13: ...O OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMP...

Page 14: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 14 APPENDIX...

Page 15: ...cal Latching Relays Switcher Router SS 8 1 MLR RJ 1 Configuration SW1 Switcher Router 1 Configuration Enable Switch Jumper JP1 Front Panel Dip Switch 1 Configuration SW1 Dip Switch 1 Configuration Mod...

Page 16: ...Fractional Schematic w Mechanical Latching Relays Switcher Router SS 8 1 MLR RJ Switcher Router Modified 04 29 21 131 State Street Sedro Woolley WA 98284 360 854 9559 Fax 866 783 1742 Copyright 1989 2...

Page 17: ...peration Manual Fractional Schematic SS 8 1 MLR RJ Switcher Router w Mechanical Latching Relays 131 State Street Sedro Woolley WA 98284 360 854 9559 Fax 866 783 1742 Visit us online at www broadcastto...

Page 18: ...peration Manual Fractional Schematic SS 8 1 MLR RJ Switcher Router w Mechanical Latching Relays 131 State Street Sedro Woolley WA 98284 360 854 9559 Fax 866 783 1742 Visit us online at www broadcastto...

Page 19: ...peration Manual Fractional Schematic SS 8 1 MLR RJ Switcher Router w Mechanical Latching Relays 131 State Street Sedro Woolley WA 98284 360 854 9559 Fax 866 783 1742 Visit us online at www broadcastto...

Page 20: ...peration Manual Fractional Schematic SS 8 1 MLR RJ Switcher Router w Mechanical Latching Relays 131 State Street Sedro Woolley WA 98284 360 854 9559 Fax 866 783 1742 Visit us online at www broadcastto...

Reviews: