SS 4.1 Plus Installation and Operation Manual

INSTALLATION

STEP 3: BENCH TEST and OPTIONS

Place each unit on a workspace and connect power to the unit.  Check to see if LED
#1 (Channel 1) and the PWR LED are lit (Source one is the power-up factory
default).  Connect an audio source to stereo input one and a monitoring device to the
output. Verify that audio is present.   Repeat the process until each channel’s opera-
tion has been verified.  

Jumper JP2 

To enable the front panel “ENABLE” switch, remove and stow the jumper over
the “Enable Bypass” jumper JP2.  

Note:  The “Enable” switch is disabled at the factory.

Dipswitches:

DIP (SW6) Switch Functions
Unit ID

SW6-1

SW6-2

SW6-3

ID 0  *

OFF

OFF

OFF

ID 1

ON

OFF

OFF

ID 2

OFF

ON

OFF

ID 3

ON

ON

OFF

ID 4

OFF

OFF

ON

ID 5

ON

OFF

ON

ID 6

OFF

ON

ON

ID  7

ON

ON

ON

Baud RateSW6-4

SW6-5

2400

ON

OFF

9600  *

OFF

OFF

4800

OFF

ON

38400

ON

ON

Power Up

SW6-6

User selected

ON

Last source 

OFF

selected  *

Remote/PIP

SW6-7

PIP / Triggers

ON

Remote Control  *

OFF

Note:

* Denotes factory setting.

Note:  After changing any dipswitch, please repower the unit.

!

TIP

The “ACT” (audio
activity) LED is an
excellent audio output
indicator.

NOTE:

Input selection at
power-up may be con-
figured by holding down
the desired channels
push button until the
mute and Pwr/Ser
LED’s flash.  Factory
power-up default is
channel one.  

Summary of Contents for SS 4.1 Plus

Page 1: ...porate such changes Broadcast Tools is a registered trademark of Broadcast Tools Inc tiny TOOLS is a trademark of Broadcast Tools Inc All Sentinel labeled products are a trademark of Broadcast Tools I...

Page 2: ...ntents Section Title Page Introduction 3 Safety Information 3 Who to Contact for Help 3 Product Description 4 Features 4 Applications 4 Front Panel Description 5 Rear Panel Description 5 Installation...

Page 3: ...software problems If you experience these problems please research your hardware software instruction manuals or contact the man ufacturers technical support department WHO TO CONTACT FOR HELP If you...

Page 4: ...h a front panel LED indi cator SPST alarm relay and adjustable SS alarm delay and restore timing duration The ACT circuit performs as an audio output activity monitor with front panel LED indicator Th...

Page 5: ...k is provid ed for the multi drop bi directional RS 232 serial port Power Connect the 2 1mm coaxial type power connector into the unit and the 9 VAC 1 amp wall transformer into a 120 Vac 50 60 Hz powe...

Page 6: ...er immediate ly and retain the packaging for inspection by the shipper The package should contain the SS 4 1 Plus this manual and or CD the manual may be downloaded from our web site 9 VAC 1 amp trans...

Page 7: ...the Enable Bypass jumper JP2 Note The Enable switch is disabled at the factory Dipswitches DIP SW6 Switch Functions Unit ID SW6 1 SW6 2 SW6 3 ID 0 OFF OFF OFF ID 1 ON OFF OFF ID 2 OFF ON OFF ID 3 ON...

Page 8: ...ear side of the chassis Before installing a wire remove the plug in euroblock screw terminal and turn each capture screw fully counterclockwise Strip each conductor to a length of 0 25 and insert the...

Page 9: ...nals located on the rear panel The SS 4 1 Plus accepts momentary contact closures sustained if break before make open collector or TTL CMOS input logic levels Connections to the remote control and or...

Page 10: ...he SS 4 1 Plus The protocol is as follows 2400 4800 9600 38400 8N1 Flow control should be set to NONE emulation to ANSI and the mode should be set to DIRECT TO COMx x the available com port The defaul...

Page 11: ...n of the last channel in the step front panel lock audio channel selection with status and audio status The stepping time can be between 1 and 99 seconds The last channel step is selec table from chan...

Page 12: ...en collector or contact closures to ground 50 ms response time in PIP trigger mode Serial Multi drop RS 232 Bi directional 2400 4800 9600 38400 8 N 1 Status Front Panel Indicator LED s Remote Audio AC...

Page 13: ...OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPL...

Reviews: