Broadcast Tools SS 4.1 Plus Installation And Operation Manual Download Page 6

e-mail: 

[email protected]   

voice: 

360.854.9559   

fax: 

866.783.1742

6

SS 4.1 Plus Installation and Operation Manual

INSTALLATION

Installation Guidelines

It is recommended that all cables connected to the SS 4.1 Plus be looped through fer-
rite cores to suppress RF.  Surge protection with RF filtering such as the Tripp Lite
“ISOBAR 4” is also suggested for the power transformer. The purchase of an inex-
pensive uninterruptible power supply (UPS) will provide back up in case of power
outages.  Check out our web site for lightning protection links.

The SS 4.1 Plus is simple to install.  The signal inputs, outputs are connected via
plug-in euroblock screw terminals.  Installation of the SS 4.1 Plus consists of seven
steps:

1. Inspection
2. 

Removal of the source termination resistors, if applicable

3.

Bench test and option set-up

4. 

Mount the unit in a rack (RA-1), desktop or wall 

5.  

Connect your equipment to the unit

6. 

Label the front panel switches

7.

Serial operation, if applicable

STEP 1: INSPECTION

Please examine your SS 4.1 Plus carefully for any damage that may have been
sustained during shipping.  If any is noted, please notify the shipper immediate-
ly and retain the packaging for inspection by the shipper.  The package should
contain the SS 4.1 Plus, this manual and/or CD (the manual may be downloaded
from our web site), 9 VAC @ 1-amp transformer, reversed modular cable, 9-pin
female “S9” D-Sub adapter and audio and remote control mating connectors.

STEP 2: SOURCE TERMINATION RESISTOR REMOVAL

Input sources that are 

NOT

selected are terminated with a 10K W resistor.  If you

do not require this load applied to the deselected sources, it may be removed from
each channel.  Each channel has a pair of resistors.  Removal information:  Channel
1 = R 8 & R9.  Channel 2 = R10 & R11.  
Channel 3, R12 & R13 and Channel 4 = R14 & R15.  If the unit is to be used for
applications other than switching audio, the Silence Sensor and ACT detection cir-
cuit should be disabled.  To disable, remove the following components:  R24, R25
and RP9.

CAUTION!

Installation of the SS 4.1
Plus in high RF environ-
ments should be per-
formed with care.
Shielded cable is sug-
gested for all control,
audio inputs and out-
puts.  All shields should
be tied to the “GND”
terminal.   The station
ground should be con-
nected to the chassis
ground screw (CH1)
located behind J1, as
viewed from the rear.
For lightning protec-
tion, check out
www.polyphaser.com
and www.itwlinx.com

WEBSITE:

Visit our web site for
product updates and
additional information.

Summary of Contents for SS 4.1 Plus

Page 1: ...porate such changes Broadcast Tools is a registered trademark of Broadcast Tools Inc tiny TOOLS is a trademark of Broadcast Tools Inc All Sentinel labeled products are a trademark of Broadcast Tools I...

Page 2: ...ntents Section Title Page Introduction 3 Safety Information 3 Who to Contact for Help 3 Product Description 4 Features 4 Applications 4 Front Panel Description 5 Rear Panel Description 5 Installation...

Page 3: ...software problems If you experience these problems please research your hardware software instruction manuals or contact the man ufacturers technical support department WHO TO CONTACT FOR HELP If you...

Page 4: ...h a front panel LED indi cator SPST alarm relay and adjustable SS alarm delay and restore timing duration The ACT circuit performs as an audio output activity monitor with front panel LED indicator Th...

Page 5: ...k is provid ed for the multi drop bi directional RS 232 serial port Power Connect the 2 1mm coaxial type power connector into the unit and the 9 VAC 1 amp wall transformer into a 120 Vac 50 60 Hz powe...

Page 6: ...er immediate ly and retain the packaging for inspection by the shipper The package should contain the SS 4 1 Plus this manual and or CD the manual may be downloaded from our web site 9 VAC 1 amp trans...

Page 7: ...the Enable Bypass jumper JP2 Note The Enable switch is disabled at the factory Dipswitches DIP SW6 Switch Functions Unit ID SW6 1 SW6 2 SW6 3 ID 0 OFF OFF OFF ID 1 ON OFF OFF ID 2 OFF ON OFF ID 3 ON...

Page 8: ...ear side of the chassis Before installing a wire remove the plug in euroblock screw terminal and turn each capture screw fully counterclockwise Strip each conductor to a length of 0 25 and insert the...

Page 9: ...nals located on the rear panel The SS 4 1 Plus accepts momentary contact closures sustained if break before make open collector or TTL CMOS input logic levels Connections to the remote control and or...

Page 10: ...he SS 4 1 Plus The protocol is as follows 2400 4800 9600 38400 8N1 Flow control should be set to NONE emulation to ANSI and the mode should be set to DIRECT TO COMx x the available com port The defaul...

Page 11: ...n of the last channel in the step front panel lock audio channel selection with status and audio status The stepping time can be between 1 and 99 seconds The last channel step is selec table from chan...

Page 12: ...en collector or contact closures to ground 50 ms response time in PIP trigger mode Serial Multi drop RS 232 Bi directional 2400 4800 9600 38400 8 N 1 Status Front Panel Indicator LED s Remote Audio AC...

Page 13: ...OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPL...

Reviews: