SS 2.1 MLR/TERM Installation and Operation Manual
INSTALLATION
Sage ENDEC EAS Installation Guidelines
The SS 2.1 MLR/TERM can be set to a special Multi-Station Relay Panel (MSRP)
EAS switcher emulation mode which enables it to receive the serial control com-
mands sent by the Sage Digital ENDEC EAS system. You can operate up to four
independent stations off of one Sage Digital ENDEC by using one SS 2.1
MLR/TERM per station.
To use the SS2.1 MLR/TERM in EAS switcher mode with an ENDEC you must set
the DIP switch SW-5 for the proper unit ID, station ID, and mode of operation.
Unit ID
SW5-1
SW5-2
ID 0 *
OFF
OFF
ID 1
ON
OFF
Station ID
SW5-3
SW5-4
1*
OFF
OFF
2
ON
OFF
3
OFF
ON
4
ON
ON
Mode
SW5-6
SW5-7
EAS/MSRP
OFF
ON
* Denotes factory default setting.
Note: After changing any DIP switch, please re-power the unit.
Connecting a single SS 2.1 MLR/TERM to the Sage ENDEC serial port:
Attach the supplied “S9” DB-9 female adapter to a Sage ENDEC COM port con-
figured for “Relay,” 1200 baud, and the desired station ID. Connect the S9 modular
cable to the RJ11 jack on the SS 2.1 MLR/TERM. Make sure SW-5 on the SS 2.1
MLR/TERM is configured according to the settings listed above.
Set the Sage ENDEC’s MSRP settings.
Connecting two or more SS 2.1 MLR/TERMs to the Sage ENDEC Serial Port:
Multiple SS 2.1 MLR/TERMs may be cascaded serially to operate from the same
serial port by assigning unique unit/station ID’s to each SS 2.1 MLR/TERM.
Once the SS2.1 MLR/TERMs are configured properly they can be attached in par-
allel to the ENDEC using a duplex modular adapter such as the Allen-Tel AT202-6
in conjunction with the S9 adapter and reverse modular cables. Plug the male end of
the duplex modular adapter into the supplied female “S9”, DB-9 to RJ-11 adapter,
then attach one end of the supplied reversed modular line cords into each of the
duplex modular adapter receptacles and the other ends into each of the SS 2.1
MLR/TERM modular receptacles. Three or more SS 2.1 III/TERM’s may be daisy
chained by using the above description and a 5-jack modular adapter such as the
Allen-Tel AT150.