SS 2.1 MLR/TERM Installation and Operation Manual

OVERVIEW

Product Overview

The SS 2.1 MLR/TERM is a transparent two input, dual output switcher/router with
mechanical latching relays. The SS 2.1 MLR/TERM is perfect for all types of pas-
sive signal switching via front panel switches, contact closures and/or serial RS-232.
The switching is accomplished with mechanical latching gold contact relays, which
means that the unit can route a signal in either direction. Due to the passive nature
of the switching, any input level and impedance can be used. Inputs may be balanced
or unbalanced, while output levels, impedance, distortion, noise and balancing will
match that of the selected input. The SS 2.1 MLR/TERM can be controlled and mon-
itored locally and/or with simple contact closures to ground, as well with multi-drop
RS-232 serial commands. 

Features/Benefits

• Front panel channel selection push buttons with active channel LED indicators.
• The audio “MUTE” function allows the user to turn off all audio.
• Front panel Enable switch can be configured to provide a safety lock to the front

panel selection push buttons.

• Remote control via contact closures, 5-volt TTL/CMOS logic levels and/or the

multi-drop RS-232 serial port.  TCP/Telnet control/monitoring with our option-
al ESS-1, RS-232 to Ethernet adapter.

• Two SPDT relay outputs for remote channel status.
• Internal silence sensor with front panel LED indicator; separate SPST silence

sensor alarm relay, adjustable alarm delay and restore duration.

• Audio/signal switching via mechanical latching sealed relays utilizing 2-form-C

bifurcated - crossbar silver alloy with gold overlay contacts.

• Removable euro-block screw terminal connectors are used for audio/signal I/O

and remote control connections. Necessary mating plugs are supplied.

• The power-up source selection feature allows the user to select which source is

active at power up, including the last source selected.

• If power is lost, the last selected channel is passed to the output.
• Fully RFI proofed.
• Surge protected internal power supply, domestic power supply provided.

Optional CE 240 Vac 50-60 Hz power supply available.

• Up to three units may be mounted on the optional RA-1 rack shelf.  Desk top and

wall mounting is also possible.

Applications

Switching/routing applications include: Analog and/or AES audio sources, Studio
selection, Audio processing selection, EAS audio, RS-232, RS-422 or RS-485 data
signals and telephone lines. 

WEBSITE:

Visit our web site for
product updates and
additional information.

Summary of Contents for SS 2.1 MLR/TERM

Page 1: ...ls Inc All Sentinel labeled products are registered trademarks of Broadcast Tools Inc Copyright 1989 2012 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distr...

Page 2: ...on Operation 5 Selection push buttons 5 LED indicators 5 Power 5 I O and Remote Control Connectors 6 Remote Control Wiring 6 Control 6 Relays 6 Configuration Jumpers 6 Configuration DIP switch setup 7...

Page 3: ...tup of the SS 2 1 MLR TERM Broadcast Tools Inc is unable to support NON Broadcast Tools software hardware or NON Broadcast Tools computer hard ware software problems If you experience these problems p...

Page 4: ...emote control via contact closures 5 volt TTL CMOS logic levels and or the multi drop RS 232 serial port TCP Telnet control monitoring with our option al ESS 1 RS 232 to Ethernet adapter Two SPDT rela...

Page 5: ...em AUPS helps minimize the risk to the SS 2 1 MLR TERM and provides power during a power outage NOTE If power is lost the last selected channel is passed to the output Installation Operation Selection...

Page 6: ...witcher is via the bottom row of the connector TB4 Each channel may be selected by a momentary or sustained depending on the configu ration contact to ground Each channel is pulled high 5 volts throug...

Page 7: ...p with SW5 5 ON hold down the push but ton for the desired input channel or mute until the front panel LED s flash Operation SW5 6 SW5 7 Normal OFF OFF Sustained ON OFF EAS MSRP OFF ON Toggle ON ON No...

Page 8: ...M port con figured for Relay 1200 baud and the desired station ID Connect the S9 modular cable to the RJ11 jack on the SS 2 1 MLR TERM Make sure SW 5 on the SS 2 1 MLR TERM is configured according to...

Page 9: ...es start of string character Unit ID address 0 through 3 i Input channel 1 2 or M MUTE i Switch to input i M Mute audio output Turn Off Audio SL Send Audio Status SuL1 x x cr lf Note x 0 OFF x 1 ON SS...

Page 10: ...5 volts CMOS TTL logic open collector or contact closures to ground Serial Multi drop RS 232 2400 9600 19200 38400 8 N 1 Status Front Panel LED Indicators Remote Two SPDT relays 1 amp 30 vdc Refer to...

Page 11: ...NO OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IM...

Page 12: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 12 SS 2 1 MLR TERM Installation and Operation Manual APPENDIX FRONT PANEL REAR PANEL...

Page 13: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 SS 2 1 MLR TERM Installation and Operation Manual 13 APPENDIX...

Page 14: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 SS 2 1 MLR TERM Installation and Operation Manual 14 APPENDIX...

Page 15: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 SS 2 1 MLR TERM Installation and Operation Manual 15 APPENDIX...

Reviews: