e-mail:
voice:
360.854.9559
fax:
866.783.1742
9
SS 2.1 MLR/RJ Installation and Operation Manual
CONFIGURATION
Sage ENDEC EAS Installation Guidelines/MSRP Mode
The SS 2.1 MLR/RJ can be set to a special Multi-Station Relay Panel (MSRP) EAS
switcher emulation mode which enables it to receive the serial control commands
sent by the Sage Digital ENDEC EAS system. You can operate up to four independ-
ent stations from one Sage Digital ENDEC by using one SS 2.1 MLR/RJ per station.
To use the SS2.1 MLR/RJ in EAS switcher mode with an ENDEC you must set the
DIP switch SW-5 for the proper unit ID, station ID, and mode of operation.
Unit ID
SW5-1
SW5-2
ID 0 *
OFF
OFF
ID 1
ON
OFF
Station ID
SW5-3
SW5-4
1*
OFF
OFF
2
ON
OFF
3
OFF
ON
4
ON
ON
Mode
SW5-6
SW5-7
EAS/MSRP
OFF
ON
* Denotes factory default setting.
Note: After changing any DIP switch, please re-power the unit.
Connecting a single SS 2.1 MLR/RJ to the Sage ENDEC serial port:
Attach the supplied “S9” DB-9 female adapter to a Sage ENDEC COM port con-
figured for “Relay,” 1200 baud, and the desired station ID. Connect the S9 modular
cable to the RJ11 jack on the SS 2.1 MLR/RJ. Make sure SW-5 on the SS 2.1
MLR/RJ is configured according to the settings listed above.
Set the Sage ENDEC’s MSRP settings.
Connecting two or more SS 2.1 MLR/RJs to the Sage ENDEC Serial Port:
Multiple SS 2.1 MLR/RJs may be cascaded serially to operate from the same serial
port by assigning unique unit/station IDs to each SS 2.1 MLR/RJ.
Once the SS2.1 MLRs are configured properly they can be attached in parallel to the
ENDEC using a duplex modular adapter such as the Allen-Tel AT202-6 in conjunc-
tion with the S9 adapter and reverse modular cables. Plug the male end of the duplex
modular adapter into the supplied female “S9”, DB-9 to RJ-11 adapter, then attach
one end of the supplied reversed modular line cords into each of the duplex modu-
lar adapter receptacles and the other ends into each of the SS 2.1 MLR/RJ modular
receptacles. Three or more SS 2.1’s may be daisy chained by using the above
description and a 5-jack modular adapter such as the Allen-Tel AT150.
WEBSITE:
Visit our web site for
product updates and
additional information.