Broadcast Tools SS 2.1 MLR/RJ Installation And Operation Manual Download Page 9

e-mail: 

[email protected]   

voice: 

360.854.9559   

fax: 

866.783.1742

9

SS 2.1 MLR/RJ Installation and Operation Manual

CONFIGURATION

Sage ENDEC EAS Installation Guidelines/MSRP Mode

The SS 2.1 MLR/RJ can be set to a special Multi-Station Relay Panel (MSRP) EAS
switcher emulation mode which enables it to receive the serial control commands
sent by the Sage Digital ENDEC EAS system. You can operate up to four independ-
ent stations from one Sage Digital ENDEC by using one SS 2.1 MLR/RJ per station.

To use the SS2.1 MLR/RJ in EAS switcher mode with an ENDEC you must set the
DIP switch SW-5 for the proper unit ID, station ID, and mode of operation.

Unit ID

SW5-1

SW5-2

ID 0 * 

OFF

OFF

ID 1

ON

OFF

Station ID

SW5-3

SW5-4

1*

OFF

OFF

2

ON

OFF

3

OFF

ON

4

ON

ON

Mode

SW5-6

SW5-7

EAS/MSRP

OFF

ON

* Denotes factory default setting.

Note: After changing any DIP switch, please re-power the unit.

Connecting a single SS 2.1 MLR/RJ to the Sage ENDEC serial port:

Attach the supplied “S9” DB-9 female adapter to a Sage ENDEC COM port con-
figured for “Relay,” 1200 baud, and the desired station ID. Connect the S9 modular
cable to the RJ11 jack on the SS 2.1 MLR/RJ. Make sure SW-5 on the SS 2.1
MLR/RJ is configured according to the settings listed above.
Set the Sage ENDEC’s MSRP settings.

Connecting two or more SS 2.1 MLR/RJs to the Sage ENDEC Serial Port:

Multiple SS 2.1 MLR/RJs may be cascaded serially to operate from the same serial
port by assigning unique unit/station IDs to each SS 2.1 MLR/RJ.

Once the SS2.1 MLRs are configured properly they can be attached in parallel to the
ENDEC using a duplex modular adapter such as the Allen-Tel AT202-6 in conjunc-
tion with the S9 adapter and reverse modular cables. Plug the male end of the duplex
modular adapter into the supplied female “S9”, DB-9 to RJ-11 adapter, then attach
one end of the supplied reversed modular line cords into each of the duplex modu-
lar adapter receptacles and the other ends into each of the SS 2.1 MLR/RJ modular
receptacles. Three or more SS 2.1’s may be daisy chained by using the above
description and a 5-jack modular adapter such as the Allen-Tel AT150.

WEBSITE:

Visit our web site for
product updates and
additional information.

Summary of Contents for SS 2.1 MLR/RJ

Page 1: ...roducts are registered trademarks of Broadcast Tools Inc Copyright 1989 2020 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed without permission Vis...

Page 2: ...sh buttons 5 LED indicators 5 Power 5 Chassis Ground 5 I O and Remote Control Connectors 6 RJ45 Pinout 6 Remote Control Wiring 7 Relays 7 RS 232 Serial Port 7 Configuration Jumpers 8 Configuration DIP...

Page 3: ...f the SS 2 1 MLR RJ Broadcast Tools Inc is unable to support NON Broadcast Tools software hardware or NON Broadcast Tools computer hardware software problems If you experience these problems please re...

Page 4: ...push buttons Remote control via contact closures 5 volt TTL CMOS logic levels and or the multi drop RS 232 serial port Two SPDT relay outputs for remote channel status Internal silence sensor with fr...

Page 5: ...e passively routed to the output Installation Operation Input selection push buttons Each input and mute can be selected via its front panel push button labelled 1 2 and Mute respectively Each input p...

Page 6: ...ire this load applied to the deselected sources they may be removed or a different value may be substituted for each channel Each channel has a pair of resistors channel 1 R1 R2 channel 2 R3 R4 If you...

Page 7: ...The relay K3 is closed when with input channel one is selected K4 is closed when input channel two is selected and relay K5 SPST is closed when silence is detected if enabled Note For wiring informati...

Page 8: ...guration options Unit ID SW5 1 SW5 2 ID 0 OFF OFF ID 1 ON OFF ID 2 OFF ON ID 3 ON ON Baud Rate SW5 3 SW5 4 2400 ON OFF 9600 OFF OFF 19200 OFF ON 38400 ON ON Power Up SW5 5 User selected ON Last source...

Page 9: ...Sage ENDEC COM port con figured for Relay 1200 baud and the desired station ID Connect the S9 modular cable to the RJ11 jack on the SS 2 1 MLR RJ Make sure SW 5 on the SS 2 1 MLR RJ is configured acco...

Page 10: ...D sub adapter pinout Serial Commands The switcher may be controlled and monitored by burst serial strings or by the embedded setup menu Where the Denotes start of string character u Unit ID address 0...

Page 11: ...ates and additional information CONFIGURATION Menu Operation Broadcast Tools R SS2 1MLR v1 11 Setup Menu 1 Set Silence Sense Acquire Delay sec Now 10 2 Set Silence Sense Restore Delay sec Now 2 3 Set...

Page 12: ...Status Front Panel LED Indicators Remote Two SPDT status relays One SPST Silence Sense relay 1 amp 30 VDC max Refer to the fractional schematic and or text on the rear panel for connection details CAU...

Page 13: ...O OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMP...

Page 14: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 14 APPENDIX...

Page 15: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 15 APPENDIX...

Page 16: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 16 APPENDIX...

Page 17: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 17 APPENDIX...

Reviews: