SRC-16 Plus Installation and Operation Manual
SETUP
Setup/Operation
Configuration Dip-switch Setup
The configuration dip-switch package (SW1) labelled “Options” is located on front
panel of the SRC-16 Plus.
Note: After changing any dip-switch, please repower the unit.
Set Unit ID (SW1-1, SW1-2)
SW1-1
SW1-2
OFF
OFF
Unit ID 0 (master/default)
OFF
ON
Unit ID 1
ON
OFF
Unit ID 2
ON
ON
Unit ID 3
Set Serial Baud Rate (SW1-3, SW1-4)
SW1-3
SW1-4
OFF
OFF
9,600 baud (default)
OFF
ON
1,200 baud
ON
OFF
4,800 baud
ON
ON
38,400 baud
Baud rate will be set by the DIPswitch on power up or reset. It can also be
changed using the serial port commands at other times, but if the SRC-16 is reset,
baud rate will be set according to the DIP settings.
Enable Hex Mode (SW1-5)
SW1-5
OFF
Hex Mode Off (ASCII) (default)
ON
Hex Mode On
Refer to the protocol also listed in this manual for ASCII and binary hex commands.
Set Operation Mode (SW1-6, SW1-6, SW1-8)
SW1-6
SW1-7
SW1-8
OFF
OFF
OFF
Mode 0 - PC Control
OFF
OFF
ON
Mode 1 - AT1616 Command Set
OFF
ON
OFF
Mode 2 - *uiix
OFF
ON
ON
Mode 3 - Invert send and poll response
bits
ON
OFF
OFF
Mode 4 - PAIR
ON
OFF
ON
Mode 5 - Unused
ON
ON
OFF
Mode 6 - Data Programming Mode
ON
ON
ON
Mode 7 - Data Mode
PC Control (Mode 0)
This is the default operation mode for the SRC-16 Plus. Use this mode if you plan
on exchanging ASCII string data with the SRC.