SRC-16 Plus Installation and Operation Manual

SPECIFICATIONS

SPECIFICATIONS

Digital Inputs:

16 - Selectable 5 to 24 vdc optically Isolated inputs
(Jumper selectable. Factory default = Dry). 50 ms
minimum duration. 

Note:  Higher voltages with external current limit-
ing resistor.

Relay Outputs:

16 - SPDT, 1 amp/30 VDC relays.  Jumper selectable
either N.O or N.C  Factory default = N.O.

RS-232 Serial Port:

4,800, 9,600, 19,200 or 38,400 baud, 8 data bits, no
parity, 1 stop bit.

RS-422 Serial Port:

4,800, 9,600, 19,200 or 38,400 baud, 8 data bits, no
parity, 1 stop bit.

Display:

LED’s for inputs, relays, Tx & Rx serial data and
power.

Interfacing:

Inputs – Plug-in euroblock screw terminals.
Relays - Plug-in euroblock screw terminals.
RS-232 Serial Port - Female DB-9.  Data flow pro-
grammable.
RS-422/485 Serial port - Plug-in euroblock screw ter-
minals.
Expansion port - Two, RJ45 connectors.

Logic:

Flash microprocessor / Non-volatile memory.

Power:

9 VDC @ 670ma, surge protected universal input wall
transformer supplied. 2.1mm center positive coaxial
jack. International AC power plug adapters optional.

Mechanical:

8.50" x 7.125” x 1.00", aluminum chassis and steel
front panel.

Weight:

4 lbs.

Mounting Option:

Optional RA-1 rack shelf for mounting up to two units
in 1-RU.  Filler panels included.

Ethernet Option:

Optional external Ethernet Device Server.

USB Option:

Optional external Smart USB to Serial adapter.
Broadcast Tools® Smart USB to RS232 cable.

WEBSITE:

Visit our web site for
product updates and
additional information.

Summary of Contents for SRC-16 Plus

Page 1: ...l Sentinel labeled products are registered trademarks of Broadcast Tools Inc Copyright 1989 2013 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed wi...

Page 2: ...Panel Description 5 LED Indicators 5 Configuration Dip switch 5 Rear Panel Description 6 Power 6 Status Logic Inputs 6 Relay Outputs 7 Expansion Ports 7 Serial Connections 7 Setup Operation Configura...

Page 3: ...6 PLUS Broadcast Tools Inc is unable to support NON Broadcast Tools software hardware or NON Broadcast Tools computer hardware software problems If you experience these problems please research your h...

Page 4: ...may be operated in a standalone pair mode to form a Relay extension cord with 16 channels of control in each direction The unit can com municate using RS 232 RS 422 or RS 485 at data rates up to 38 40...

Page 5: ...built in resistance to voltage changes we recommend that you use a power surge protector or line conditioner on the incoming AC line Lightning strikes and or other high voltage surges may damage your...

Page 6: ...is the status logic input and the header pins 1 2 3 4 are used to con figure for WET or DRY operation The factory default is DRY Switch relay con tact open collector with jumpers between 1 2 and 3 4...

Page 7: ...the included red Cat5 patch cable RS 232 Serial Connection The RS 232 serial connection is made to the male DB 9 connector on the back of the SRC 16 Plus The headers labeled RS 232 NNRR on the SRC s...

Page 8: ...t by the DIPswitch on power up or reset It can also be changed using the serial port commands at other times but if the SRC 16 is reset baud rate will be set according to the DIP settings Enable Hex M...

Page 9: ...2A3C9 To set relays ON send a capital P followed by two ASCII hex bytes representing the bits for the lower 8 relays and a capital Q followed by two ASCII hex bytes representing the state of the upper...

Page 10: ...a unit does not receive an update from its corresponding paired unit for a period of about 10 seconds it will begin flashing the red RX LED one second on one second off When communication is restored...

Page 11: ...or the program time out DATA SENT BY INPUTS 01 123 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 ENTER 01 16 FOLLOWED BY DATA STRING UP TO 64 BYTES END WITH CR Programming Relay Control Strings In Data...

Page 12: ...command starts with an asterisk Next is a single decimal digit that corresponds to the unit ID address 0 3 Following is or more ASCII charac ter s specifying the command A carriage return is required...

Page 13: ...end status of input where ii input number Response in SuP ii x format where x is 1 if the corresponding input is high 0 otherwise Command Example 0SP01 Poll Input 01 status Response Example S0P 01 1 I...

Page 14: ...02 46 72 Enable error good responses 47h 2A 02 47 73 Disable error good responses 48h n 2A 03 48 01 76 Latch output n 00 0F 49h n 2A 03 49 01 77 Unlatch output n 00 0F 4Bh n 2A 03 4B 01 79 Poll outpu...

Page 15: ...2 010b Byte count 2 00010b 01001101b 4Dh All Output Status Request 10111001b B9h Check sum 2Ah 42h 4Dh B9h Response string from SRC 16 Plus 00101010b 2Ah Start byte 01000100b 44h Board ID 2 010b Byte...

Page 16: ...ower Interfacing Inputs Plug in euroblock screw terminals Relays Plug in euroblock screw terminals RS 232 Serial Port Female DB 9 Data flow pro grammable RS 422 485 Serial port Plug in euroblock screw...

Page 17: ...OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPL...

Page 18: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 18 APPENDIX...

Page 19: ...Product_Name Installation and Operation Manual e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 19 APPENDIX...

Page 20: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 20 APPENDIX...

Page 21: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 21 APPENDIX...

Page 22: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 22 APPENDIX...

Reviews: