Smart Relay 4 G2 Installation and Operation Manual
OPERATION
Mode Settings
Mode 00: Relay output closes when the odd input is active and opens when the odd
input is inactive. (Factory Default)
Mode 01: Relay output toggles on leading edge of the odd input.
Mode 02: Relay output closes on the leading edge of the odd input. Relay remains
closed until the leading edge of the even input is active.
Mode 03: Relay output closes after the odd input has been active for the pro-
grammed time period. It opens after the even input is closed for the time period.
Mode 04: Relay closed on the leading edge of the odd input. The relay opens after
the trailing edge is closed for the time period.
Mode 05: Relay output closes on leading edge of the odd input for time period.
Mode 06: Relay output closes for the time period on the trailing edge of the odd
input.
Mode 07: Relay output closes for the time period on the leading or trailing edge of
the
odd input.
Mode 08: Relay output closes on leading edge of the odd input and remains closed
for at least the time period. If the odd input stays active for longer than the time peri-
od, the relay will open on the trailing edge of the odd input.
Mode 09: Relay output closes on the leading edge of the odd input for no longer than
the time period. If a trailing edge is encountered before the time has expired, the
relay will open with the edge. Otherwise, the relay opens when the time period
expires.