e-mail:
voice:
360.854.9559
fax:
866.783.1742
7
DTD-16 Plus Installation and Operation Manual
PROGRAMMING
Momentary
If you have selected the momentary function for this output channel, you can enter two
codes up to 5 digits for the first code and 6 digits for the second code that can be used to
activate that output. If your code is shorter than 5 digits enter a “/” at the end of the first
data string. This will cause a new line to be displayed. Enter the second code you want
to momentarily trigger. If the string is less than 6 digits press the “Enter” key. The codes
for that output will now be saved and you can go on to programming another output.
Momentary Example:
Momentary Example: To program output 1 for momentary for code 123 and 321 with a
time delay of 4.25 seconds before activation:
01-
0
4.25
123/
321(CR)
Latch
For the Latch Function, the first code will be used to latch the output on, and the sec-
ond code to turn it off. Enter the “ON” code, from 1 to 6 digits. If it is shorter than 5
digits, terminate with the “/” character. A new line will be displayed. Now enter the code
you want to use to turn OFF that output. It must be from 1 to 6 digits long. If it is short-
er than 6 digits terminate with the “Enter” key. You cannot enter the same code to latch
an output on and turn it off.
Latch Example:
To program output 2 for 456 latch on, 654 latch off with no time delay:
02
1
0.00
456/
654
Exclusive Latch
For the Exclusive Latch function, the first code will be used to latch the output on,
and the second code to turn it OFF, if desired. You do not need to enter an OFF code.
In Exclusive latch mode, when any exclusive latch output is selected, all other exclusive
latch outputs will be reset. Enter the “ON” code, from 1 to 5 digits. If it is shorter than
6 digits terminate with the “/” character. A new line will be displayed. Now enter the
code you want to use to turn off that output. It must be from 1 to 6 digits long. If it is
shorter than 5 digits terminate with the “Enter” key. You cannot enter the same code to
latch an output on and turn it OFF.
Exclusive Latch Example:
To program output 3 for 789 xlatch on with time delay of .10 second:
02
2
0.10
789(CR)
To exit Program mode, press the ESC key. Also, program mode will be exited after 60 sec-
onds of inactivity. When Program mode is exited, it will list the current values and per-
form a reset.