Broadcast Tools DTD-16 Plus Installation Manual Download Page 4

e-mail: 

[email protected]   

voice: 

360.854.9559   

fax: 

866.783.1742

4

DTD-16 Plus Installation and Operation Manual

INTRODUCTION

Product Overview

The DTD-16 Plus is a full-featured DTMF tone/sequence decoder that is user pro-
grammable to decode single tones or sequences up to six tones in length and maybe
assigned to any one of eight SPST normally open relays, eight open collectors and/or
the USB serial port. The relays and open collectors may be programmed to close for
the duration of tone, pulse immediately after completion of detection, wait a pro-
grammed (up to 9.99 seconds) length of time after detection, or latch/unlatch.
Programming is performed using a non-dedicated PC’s USB port equipped with
Windows HyperTerminal and/or Putty.

Features

Decodes all 16 DTMF tones; 16 memory locations; adjustable tone detection time;
line level high Z input, which accepts a balanced or unbalanced source, surge pro-
tected power supply, front panel status for power, each relay, valid DTMF tone,
serial data activity, recessed programming push button with LED indicator and
recessed input level control with a range of -20 to +24dbu. All connections are on
removable screw terminals except for the USB Type B female port connector. The
DTD-16 Plus may be set on a desktop, mounted on a wall or up to four units
mounted on the RA-1, 1-RU mounting shelf.

Inspection

Please examine your DTD-16 Plus carefully for any damage that may have been sus-
tained during shipping. If any is noted, please notify the shipper immediately and
retain the packaging for inspection by the shipper. The package contains the DTD-16
Plus, 7.5 to 12 volt DC wall power transformer, four plastic and/or velcro feet,
USB-A/B cable and this manual on the web site or CD.  

Installation

Installation of the DTD-16 Plus in high RF environments should be performed with
care.  Shielded cable is suggested for all audio connections. All shields should be
tied to the “GND” Ground terminal. The station ground should be connected to the
CGND terminal. 

Surge Protection/RF Filtering

It is recommended that all cables connected to the DTD-16 Plus be looped through
ferrite cores to suppress RF. Surge protection with RF filtering such as the Tripp-Lite
“ISOBAR 4 or 6” is also suggested for the wall transformer.

Input Connection

Hi Z, active balanced. Connect your equipment to the AUD- and AUD+ removable
screw terminals.  If the user is feeding the unit with an unbalanced output, attach the
positive output to the + input and a jumper between the "-" input and GND

Input level

The front panel “INPUT LVL” control may be used to adjust the DTMF tone detection
from –20dBu to +24dBu. This control should be adjusted for a solid DV led indication.

WEBSITE:

Visit our web site for
product updates and
additional information.

Summary of Contents for DTD-16 Plus

Page 1: ...adcast Tools Inc tiny TOOLS is a trademark of Broadcast Tools Inc All Sentinel labeled products are registered trademarks of Broadcast Tools Inc Copyright 1989 2013 by Broadcast Tools Inc All rights r...

Page 2: ...4 Surge Protection RF suppresion 4 Input connection 4 Input level control 4 Relay connections 5 Open Collector connections 5 Dip Switch Settings 5 DTMF Tone Detection Jumper JP1 5 USB Data output 5 Po...

Page 3: ...roadcast Tools Inc is unable to support NON Broadcast Tools software hardware or NON Broadcast Tools computer hardware software problems If you experience these problems please research your hardware...

Page 4: ...a wall or up to four units mounted on the RA 1 1 RU mounting shelf Inspection Please examine your DTD 16 Plus carefully for any damage that may have been sus tained during shipping If any is noted ple...

Page 5: ...the ASCII RS 232 output This is useful for using DTMF to remotely control equipment that requires a CR LF termination This allows you to use the as an Enter key DIP 3 When DIP 3 is ON codes programme...

Page 6: ...0 0 00 6666 07 0 0 00 7777 08 0 0 00 8888 09 0 0 00 9999 10 0 0 00 0000 11 0 0 00 12 0 0 00 13 0 0 00 AAAA 14 0 0 00 BBBB 15 0 0 00 CCCC 16 0 0 00 DDDD EXIT PGM DTD 16 VER 2 00 The factory default ha...

Page 7: ...to turn OFF that output It must be from 1 to 6 digits long If it is short er than 6 digits terminate with the Enter key You cannot enter the same code to latch an output on and turn it off Latch Exam...

Page 8: ...Connectors Audio Inputs relays and open collector outputs Removable screw terminals Required power supply 7 5 to 12 0 VDC only greater than 400 ma 2 1mm ID x 5 5mm OD coaxial connector center positive...

Page 9: ...O OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW Broadcast Tools AND ITS SUPPLIERS DISCLAIM ALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO...

Page 10: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 DTD 16 Plus Installation and Operation Manual 10 APPENDIX...

Page 11: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 DTD 16 Plus Installation and Operation Manual 11 APPENDIX...

Page 12: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 DTD 16 Plus Installation and Operation Manual 12 APPENDIX...

Page 13: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 13 DTD 16 Plus Installation and Operation Manual APPENDIX Product Label...

Reviews: