Glossary Of Command Notation:
Character String
Meaning
Allowable Values
u
Unit ID
0-7
ii
Input Number
01-08
o
Output Number
1,2,3,4
oo
Open Collectors
01 – 16
Set-up Commands:
*uCCx
Ignore, set by switches
*uCEx
Enable Error and Good Responses - Where x = Y to enable
and N = disable. In this mode, when a command is sent that
is in error, the unit will reply (possibly before receiving the
entire command) with “EEE.” If the command is sent cor-
rectly, the unit will reply with “RRR.”
*CDEF
Reset to factory defaults
*uCIIttt
Set “PIP” Programmable Pulse Stretcher Input Duration = ttt:
000 – 255 Off to 2.55 Seconds.
*uCIOiittt
Ignore, send OK
*uCLx
Lock Front Panel if x is “L”. Unlock Front Panel if x is “U”
*uCRtt
Set Open Collector Momentary Pulse Length – tt:00-99 for
00 – 9.9 Seconds
*uCSAtttt
Set digital data error and/or silence sensor time delay to tttt
seconds (0002 – 9999), 0000 = OFF
*uCSBtttt
Set digital data error and/or silence sensor restore delay to tttt
seconds (0002 – 9999), 0000 = OFF
*uCSDttt
Ignore, send OK
*uCST
Ignore, send OK
*uCSVttt
Ignore, send OK
*uMCnn
Save current audio state as Macro # nn (01 à 08)
*uMInn
Invoke macro # nn (01 à 08)
*uMM
Enter menu mode if unit ID = 0
*uMS
Ignore, send OK
*uN
Ignore, send OK
Real Time Control Commands:
*uDxx
Delay xx seconds before processing next command.
*uZx
Echo character “x” to serial control port. Useful in debugging
command strings
Open Collector Output Control Commands:
*uOOrrL
Latch open collector “rr”
*uOOrrF
Unlatch open collector “rr”
*uOOrrP
Pulse open collector “rr”