e-mail:
voice:
360.854.9559
fax:
866.783.1742
12
DAS 8.4 Plus Installation and Operation Manual
INSTALLATION
Front Panel Switches:
Switch(es)
Function
1-8
Input Channels or Macros 1-8
Output 1
Output 1 selection
Output 2
Output 2 selection
Output 3
Output 3 selection
Output 4
Output 4 selection
Mute
Turn off selected I/O
Macro
Select any one of 8 Macros
Monitor Select
Select any one of the four output channels. Sequences through each out-
put each time the switch is pressed.
Front panel LED indicators:
Front Panel LED’s
# LED’s
Activation Event/Mode Activation Behavior
Inputs connected toOutput 1
8 Green
State of Connection
On if connected
Inputs connected toOutput 2
8 Yellow
State of Connection
On if connected
Inputs connected toOutput3
8 Red
State of Connection
On if connected
Inputs connected toOutput 4
8 Red
State of Connection
On if connected
Power Status
1 Green
Valid Power
On
Monitor
4 Green
Balanced output and
Any one of four output channels
headphone monitor
Macro
1 Yellow
Macro selection
On if active
“PIP” Active
1 Green
Any valid “PIP” input
On if active
Stereo 10-LED Meter
20 assorted Audio Level
Audio activity
SS
1 Red
Analog Audio Silence
On if stereo analog silence is detected
Sensor
on the selected output.
Digital Error
1 Red
Digital error
On if a digital error is detected on the
selected output.
Sample-rate
4-colors
Four sample rates
Sample rate of input signal connected to
the monitored output.
Connecting the RS-232 Serial Port:
Use the provided modular 9-pin D-sub connector adapter (S9) and reversed
modular cord to connect the DAS 8.4 Plus’s serial connector to your serial port.
The pin out of the adapter is shown below.
RJ-11
DB-9
DAS 8.4 PLUS
Adapter Pin
D-Sub
(Point of view)
4
3
RS-232 Receive
3
2
RS-232 Transmit
2
5
Ground
Modular Jack Pin Numbers