Audio Sentinel
®
+»Web Installation and Operation Manual
OPERATION
“Silence Sensor Setup” Web Page
NOTE: The delay and restore timing for both channels is 0 (OFF) to 65535 sec-
onds (18 hours, 12 minutes and 15 seconds).
Input 1 Label:
Up to 18 characters may be entered to describe input 1.
Input 1 Delay (Sec):
This is the time from when the left, right or both inputs
for input ONE fall below the trip level to when it
switches to input TWO and an alarm is generated.
Input 1 Restore Delay (Sec):
This is the time required for valid stereo audio to return
and remain present before the unit switches back to
input ONE and clears the alarm.
Input 1 Trip Level (db):
The left, right or both input levels below which input
audio is considered BAD.
Input 1 dual input mono mode:
When dual input mono mode is selected, both the left
and right inputs must be below the trip level before the
input is considered BAD and the audio is switched.
Input 1 Alarms:
When checked, the unit logs an alarm when the silence
sensor enters or exits an alarm condition, up to eight
email addresses may receive alarm emails.
Input 1 email addresses:
The boxes labeled 1-8 allow the user to assign up to
eight different email addresses for alarm notification.
Input 2 Label:
Up to 18 characters may be entered to describe input 2.
Input 2 Delay (Sec):
This is the time from when the left, right or both inputs
for input TWO fall below the trip level to when an
alarm is generated.
Input 2 Restore Delay (Sec):
This is the time required for valid stereo audio to return
and remain present before the unit clears the alarm.
Input 2 Trip Level (db):
The left, right or both input levels below which input
audio is considered BAD.
Input 2 dual input mono mode:
When dual input mono mode is selected, both the left
and right inputs must be below the trip level before the
input is considered BAD and an alarm is generated.