4
T60P Series Installation
2
3
2
1
4
FOR SHOWERHEAD INSTALLATION:
Connect top outlet (1) to shower arm (2) with
proper fittings. To prevent damage to finish on
shower arm, insert wall end of shower arm into
shower flange (3) before screwing arm into riser
connection. Thread showerhead (4) onto shower
arm. Apply Teflon
®
tape to pipe threads on both
ends. Do not overtighten showerhead.
1
Showerhead and Tub Spout Installation
FOR TUB SPOUT INSTALLATION:
Install 1/2" (13 mm) threaded pipe nipple (1) to
extend past finished wall (2) per dimension (3).
Connection of deck mount spouts to in–wall
valves is not recommended. Neither is the use
of hand showers connected to tub spouts in a
tub/shower push button diverter combination, or
hand showers connected in lieu of a tub spout
to a tub / shower valve.
1
1
(3) = 3/8" ± 1/16" (9.5 mm ± 1.5 mm)
(3) = 9/16" ± 1/16" (14.3 mm ± 1.5 mm)
(3) = 5 3/8" ± 1/16" (136.5 mm ± 1.5 mm)
1
3
2
3
2
3
2
3
(3) = 3/8" ± 1/16" (9.5 mm ± 1.5 mm)
2
RP44022
RP49126
RP49094
RP49345
Piping between valve body and tub spout must
be a minimum of 1/2" (13 mm) copper pipe or
1/2" (13 mm) iron pipe in a
straight
drop no less
than 8" (203 mm) but no more than 18" (457 mm)
long with only
one
iron pipe or copper 90 degree
elbow to the tub spout nipple. Apply Teflon
®
tape
to threads on pipe nipple and screw on tub spout.
FOR RSVP™ SHOWERHEAD AND
SHOWER ARM INSTALLATION:
Install a
1/2" threaded pipe nipple to extend beyond the
finished wall 3/8" to 1/2". Apply Teflon
®
tape to
thread on pipe nipple and screw brass adapter
(1) securely onto nipple. Apply Teflon
®
tape to
outlet end of shower arm and screw showerhead
(2) onto the shower arm (3), using provided
wrench (4) to tighten securely. Check position of
set screw on top of shower arm (3) making sure it
is not sticking through to the inside opening
where it could interfere with the assembly. Slide
shower arm and head assembly over the adapter
and tighten set screw against the adapter.
1
2
3
4