Brivo ACS100 Installation Manual

Legal Disclaimers

Federal Communications Commission (FCC) Compliancy

You are cautioned that changes or modifications not expressly approved by the part responsible for compliance 

could void the user’s authority to operate the equipment.

 

FCC 15B Class B

 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 

of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a resi-

dential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and 

used in accordance with the instructions, may cause harmful interference to radio communications. However, there 

is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful in-

terference to radio or television reception, which can be determined by turning the equipment off and on, the user 

is encouraged to try to correct the interference by one or more of the following measures:

 

1. 

Reorient or relocate the receiving antenna.

 

2. 

Increase the separation between the equipment and receiver.

 

3. 

Connect the equipment into an outlet on a circuit different from that to which the receiver is con 

 

  nected.

 

4. 

Consult the dealer or an experienced radio/TV technician for help.

This telecommunication equipment conforms to NTC technical requirement.

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two 

conditions: 

(1) this device may not cause interference, and (2) this device must accept any interference, including interference 

that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. 

L’exploitation est autorisée aux deux conditions suivantes: 

(1) l’appareil ne doit pas produire de brouillage, et (2) l’appareil doit accepter tout brouillage radioélectrique subi, 

même si le brouillage est susceptible d’en compromettre le fonctionnement.

Underwriter Laboratories (UL) Compliance

The ACS100 complies with the UL 294 Standard for access control units.

Canada-Underwriters Laboratories (C-UL) Compliancy (CSA C22.2 No. 205)

For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the Canadian Electrical Code.

 

Summary of Contents for ACS100

Page 1: ...y client site is ready for installation 6 Verify shipping contents 7 Planning the installation 7 Follow safety precautions 8 General Assembly III Assemble and mount ACS100 9 If not using PoE 11 Configuration V Connecting to the ACS100 via local area network 16 Verify connection of ACS100 to local area network 16 Wiring IV Wiring the ACS100 12 Grounding the ACS100 15 Powering the ACS100 15 ...

Page 2: ... more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is con nected 4 Consult the dealer or an experienced radio TV technician for help This telecommunication equipment conforms to NTC technical requirement This device com...

Page 3: ...K B Keypad Dual Tech Black B ACS100 E BSK W Keypad Dual Tech White Documentation Disclaimer and Restrictions Information in this document is subject to change without notice and does not represent a commitment on the part of Brivo Systems LLC For the most up to date information visit www brivo com This document and the data herein shall not be duplicated used or disclosed to others for procurement...

Page 4: ...cedures General Assembly Procedures Configuration Procedures Wiring Procedures Terminology The following is a list of terms that are used throughout this document While some of these terms may have other meanings the definitions provided below are the ones intended in this Installation Manual Control Panel Brivo s one Door Controller ACS100 is a native Ethernet and Bluetooth enabled access control...

Page 5: ...N A Cat5 Yes Yes 330 ft Request to Exit 5520FE 6300FE 22 18 Yes Yes 500 ft Door Contact 5500FE 22 Yes Yes 1500 ft Earth Ground N A 6 Yes Yes 20 to 40 ft Optional OSDP Reader N A 24 Yes Yes 1000 ft Additional Resources The following additional resources are available for the installer as well as the client ACS100 Data Sheet Panel Networking Admin Interface Guide Approved Wiegand and OSDP Reader Lis...

Page 6: ...485 A current list of compatible readers and keypads is maintained on Brivo s website at http www brivo com If you have a specific model of reader or keypad that is not listed on the Brivo website please contact Technical Support at 1 866 BRIVO 4 U to determine compatibility Verify that the client site is ready to support the installation 1 Check with the IT department to ensure that the ACS100 to...

Page 7: ...on resistors Back mounting metal plate and attachment screw Pigtail cable with connections for door I O and optional external reader Plan your installation Decide where to install the ACS100 1 If not using Power Over Ethernet PoE do not place the ACS100 more than 100 feet from the transformer This is the maximum cable run allowed by most external power supplies a Calculate the distance between the...

Page 8: ...egrees FAHRENHEIT OR exceed 120 degrees Doing so can cause damage to components within the control panel Do not install the control panel near or on the same circuit with devices that produce large amounts of electrical noise This includes grinders electric motors and blowers electrical switch gear and other electrically noisy equip ment Electrical noise can interfere with panel operation If it is...

Page 9: ...stallation Manual General Assembly Procedures Mullion Full Size Keypad Assemble and mount ACS100 1 Mount the ACS100 unit using one of the two methods described below a If using ACS100 mullion i Use two bolts on the back of the ACS100 unit to mount the ACS100 unit securely in place ACS100 Mullion Mounting ...

Page 10: ... ACS100 full size or keypad i Looking at the back of the ACS100 unit use two bolts to mount the ACS100 unit to a junction box ACS100 Full Size or Keypad Mounting c If mounting the ACS100 unit on an exterior wall surface that will receive rain or moisture run a bead of sealant around the back edge of the unit where it meets the walls ...

Page 11: ...AL If not using Power over Ethernet wire the 12 V In Orange and Ground Black wires to an external 12 VDC Power Supply 1 Use 18 AWG wire minimum grade to connect the appropriate input power wires to the ACS100 unit Connecting optional External Power to the ACS100 Model Circuit Voltage VDC Current A Brivo ACS100 E Input 12VDC 900mA ...

Page 12: ...tions ACS100 Pigtail Wiring Description ACS100 Wire Block Wire the REX DOOR CONTACT DC 1 Connect the Normally Open NO contacts of the REX device to the REX Blue and Ground Black wires a When this switch closes it initiates a Request to Exit REX program sequence as defined by the appropriate application including the option to activate the door or other relays fire the door strike and suppress any ...

Page 13: ...n use the Switched Ground to power the lock or solenoid In this scenario the ACS100 can drive up to 3A 24VDC note that the ACS100 should be powered from PoE or 12 VDC power supply 3 Devices which require a switched ground to externally drive an external device such as a PIR sensor turning on and off a mag lock can use the Switched Ground directly It can pull 650mA via the 12V output up to 104 degr...

Page 14: ...lock This will normally be at the connection from the field installed wiring to the pigtail or screw terminals of the electronic strike latch or magnetic lock 2 Use the wire recommended by the manufacturer of the electric strike or latch If no wire is recommended use a minimum of 18 AWG wire with sufficient strands for the specific electronic strike or latch Wire the optional SECOND READER 1 If yo...

Page 15: ...ices Ground the ACS100 1 When grounding the ACS100 unit use 18 AWG or larger wire to connect the ACS100 to a suitable earth ground Power up the ACS100 NOTE The ACS100 is UL listed when using DC power 1 Ensure that all wiring is complete prior to powering up the ACS100 unit 2 Plug the CAT 5 cable into the LAN PoE connector 3 If not using PoE plug in power to the ACS100 unit using 12 V In Orange and...

Page 16: ...ernet interface with an RJ45 jack for connecting the Ethernet port on the back of the ACS100 to a Local Area Network in order for it to gain connectivity to the Internet b Use a straight i e non crossover cable to connect this port to a local hub switch or router 2 Verify the connection of the LAN to the ACS100 by accessing the Administrative Interface WebCLI using the instructions listed in the p...

Reviews: