background image

1. Determine hole positions according to left and right

positions of the installation plate. The hole centre is obtained
by measuring the distances as shown in the diagram above.

2. Drill the pipe exit hole with a

65mm hole saw.

Ø

3. Drill the piping hole on either the left or right side and as required,

the hole should be slanted downwards towards the outside.

4. Always take steps to protect the pipes when drilling through

metal plate, solid structures or the like.

INSTALLATION MANUAL

Brivis HSNBR26 - 32 - 42 - 50

Inverter Hi-Wall Split System

WALL PIPE EXIT HOLE

INSTALLATION PLATE MOUNTING

I

N
D

O
O
R

U
N

I

T

Please read these safety precautions carefully before undertaking installation
Please be sure to follow the precautions as listed below, they are important for ensuring your safety.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to property.

1) This equipment must be properly earthed and installed with a circuit breaker. Electrical shock may

result if earthing is inadequate.

2) Do not install the unit in areas where leakage of flammable gases may occur. If gas leaks are allowed

to accumulate around the unit, it may cause fire.

3) Install condensate drain piping as described in the installation instructions. If drainage is insufficient

water may leak into the room and damage furniture and fixtures.

1) Install strictly in accordance with these installation instructions. If installation is defective or incomplete,

it may cause refrigerant or water leaks, electrical shock or fire.

2) Use the supplied accessories and specified parts for installation, otherwise it may cause the unit to fall,

leak water, electrical shock or fire.

3) Install in a strong firm location, sufficient to withstand the units operating weight. If the mounting is

insufficient or incomplete, the unit may fall and cause damage and/or injury.

4) Electrical installation must follow all local state and national wiring standards and regulations. A

separate and independent electrical circuit and single outlet must be used. If electrical circuit capacity

is insufficient or electrical connections are defective, it may cause electrical shock or fire.

5) Use the specified cable and ensure connections are tight. Clamp the cable so that no external forces

can be placed on the terminals. If connection is inadequate, it may cause overheating and failure.

6) Wiring routing must be properly arranged so that the control board cover is fixed properly. If the cover

is not fixed properly, it may cause overheating at the connection point and fire or electrical shock.

7) When carrying out refrigerant pipe connections, ensure that no air or other contaminants can enter

the refrigeration circuit. Otherwise, it may cause performance issues, abnormally high pressures
in the refrigeration cycle, possible explosion and/or personal injury.

8) Do not modify the length of the power supply cord or use an extension cord. Do not share the

electrical outlet with other electrical appliances. Otherwise, it may cause fire or electrical shock.

SAFETY PRECAUTIONS

CAUTION

WARNING

CAUTION

WARNING

Please read this manual carefully before operating the unit, to ensure correct installation.
If the power cord is damaged, replacement work must be performed by authorised personnel only.
Installation work must be performed in accordance with all state and national wiring standards by
authorised personnel only.
Contact an authorised service technician for repair and/or maintenance of this unit.
This appliance is not intended for use by persons (including children) with reduced physical, sensory

or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by persons responsible for their safety.
Children should be supervised to ensure that they do not play with this appliance.
The pictures in these instructions are for explanation purposes only. Please refer to actual product type.
The design and specifications are subject to change without notice for continuous product improvement.
Please contact Brivis or your Installer for details.

The unit should not be installed close to any heat sources
or where steam is prevalent.
There should be no obstacles blocking air
circulation in or around the unit.
Locate unit where air circulation/direction is best.
Locate unit where drainage setup is best.
Locate unit taking into account prevention of unwanted
noise.
Do not install the unit near doorways.
Ensure the clearances as indicated by arrows in the adjacent figures
are maintained from walls, ceilings, fences or other obstacles.
Install away from direct sunlight. If unavoidable, external
sunlight prevention should be taken into consideration.

A(m m)

B (m m)

530

290

5 60

335

Mounting dim ensions

760x590x 285

845x700x 320

Indoor unit

Outdoor unit

If a shade or awning is built over the unit to prevent
direct sunlight or rain, please be careful that heat
radiating from the condensing unit is unrestricted.
Keep unit away from any animals or plants which
could be affected by hot air discharged.
Ensure the clearances as indicated by arrows in the adjacent
figures are maintained from ceilings, fences or obstacles.
Do not place any obstructions which may cause recirculation
or short circuit of the condenser air discharge.
Do not install the unit where it may cause a noise issue for either
the home owner or neighbours, or exceed any local, state or
regulatory bodies legislative guidelines.

Secure the outdoor unit with bolts and nuts 10mm
diameter tightly and into a concrete or rigid mount.

Securing the outdoor unit

NOTE:

The outdoor unit dimensions are as per below

Install the outdoor unit according to the dimensions
as indicated in the following table:

Air inlet

Air outlet

Air inlet

INSTALLATION PRECAUTIONS

ELECTRICAL CONNECTION - INDOOR UNIT

Minimum nominal cross-sectional area of wiring:

Rated current

of appliance

( A)

> 3 up to 6

> 6 up to 10

>10 up to 16
>16 up to 25

Nominal cross-sectional

area

(mm )

2

0.75

1.0

1.5
2.5

The cable and the circuit breaker sizes

are determined by the maximum
current indicated on the nameplate

located on the side panel of the unit.
Please refer to the nameplate before
selecting the cable and circuit breaker.

Indoor unit cable connection

NOTE:

Before performing any electrical work, turn off the mains power to the system.

1. The inside and outside connection cables can be connected without removing the front grille.
2. The indoor power cord type is H05VV-F or H05V2V2-F, the outdoor power cord and

interconnected cord type is H07RN-F.

3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw.
4. Ensure the colour of wires and the terminals of the outdoor unit directly match those

of the indoor unit exactly.

5. Isolate any disconnected wiring, ensure that they cannot touch any other electrical components

or connections. Secure the cable with the cord clamp.

NOTE:

Electronic box
cover

Front Panel

1

2

3
4

5

7
8
9
10

6

Installation Plate

Clip Anchor

Self-tapping Screw A ST3.9x25

Seal
Drain Joint

Connecting
refri gerant
pi pe

Li quid

G as

Remote control

Air freshening filter (installed with Air filter)

Self-tapping Screw B ST2.9x10

Ø6.35mm
Ø9.52mm

Ø9.52mm

Ø12.7mm

Ø15.9mm

Purchased separately. The pipe sizes
differ depending on the system size.
Contact Brivis for the correct sizes.

1

5-8(depending on model)

5-8(depending on model)

1

1

1
2

1

1

With the exception of the supplied parts above, other parts required to complete the
installation must be supplied by installer.

Remote control holder

ACCESSORIES

Number

Accessory

Qty Supplied

optional

parts

SELECT THE BEST LOCATION

INTERCONNECTING PIPE AND CONDENSATE DRAIN

1. Run the condensate drain hose sloping down.

Do not install the condensate drain hose as
illustrated in the incorrect figures.

2. When connecting an extension to the condensate

drain hose, be sure to insulate the connection.

Do not run drain uphill

Do not submerge outlet

Do not allow the drain to form a trap or allow
the condensate drain hose to droop.

Condensate drain

Correct

Incorrect

1. Fit the installation plate firmly on the

structural parts of the wall with spaces
around the installation plate shown.

2. If the wall is made of brick, concrete

or the like, drill the 5mm diameter
mounting holes in the wall. Insert the
clip anchors for appropriate mounting
screws.

3. Fit the installation plate on the wall

with the type A screws.

Drill the holes and mount the installation
plate in accordance with the wall
structure and the corresponding mounting
points on the installation plate. The
installation plates provided with the
units differ from unit to unit depending
on the size. (Dimensions are in

mm unless otherwise stated)

NOTE:

NOTE:

"

"

Installation Plate Mounting

Ensure that the mounting wall is strong enough
to prevent it from vibration or failure.

Terminal block of indoor unit

To outdoor unit

To outdoor unit

Cord clamp

L

N

S

L

N

S

Electrical safety considerations prior to initial Installation
1. If there is a serious safety issue regarding the power supply, the installer should stop the installation of

the unit, fully explain the situation to the client and delay installation until the issue is resolved.

2. Power supply voltage should be in the range of 90% - 110% of the rated voltage.
3. A circuit breaker and mains power switch 1.5 times capacity of the maximum current of the unit shall be

installed in the power circuit.

4. Ensure the air conditioner is earthed correctly.
5. Wire the unit in accordance with the attached Electrical Connection Diagram located on the inside of the

panel of the outdoor unit.

6. All wiring must comply with all relevant local and national electrical codes and shall be installed only by

suitably qualified and skilled electricians.

7. An all-pole disconnection device which has at least 3mm separation distance in all poles and circuit

breaker shall be incorporated in the fixed wiring according to the local and national wiring standards.

8. A separate dedicated circuit and single power outlet must be used for this system.

See the following table for suggested wire sizes and fuse specifications:

Electrical Connection

Cor rect orientation
of nstallation late

i

p

120 or

more to wall

120 or

more to wall

120 or

more to wall

150mm or more to ceiling

150mm or more to ceiling

Left rear side

refrigerant

pipe hole Ø65

835

140

110

Left rear side

refrigerant

pipe hole Ø65

Right rear side

refrigerant

pipe hole Ø65

Right rear side

refrigerant

pipe hole Ø65

Indoor unit outline

Indoor unit outline

120 or

more to wall

120 or

more to wall

Indoor unit outline

990

135

260

150mm or more to ceiling

Left rear side

refrigerant
pipe hole

65

Ø

Right rear side

refrigerant pipe
hole

65

Ø

HSNBR42 - 50

HSNBR32

HSNBR25

120 or

more to wall

750

180

110

Reviews: