Changing a Slave to a Master Brivis Networker
• Use this method if altering a current installation or if both Brivis Networkers have been set to Slave by mistake.
• Remove the Brivis Networker off the backing plate so that the controller is powered down.
• Press and hold keys 3 & 5, then place the Brivis Networker on the backing plate ensuring keys 3 & 5 are still
depressed.
• Continue holding keys 3 & 5 for five seconds after the control is placed on the backing plate.
• After holding keys 3 & 5 for five seconds, release the two keys. The screen should now scroll this message “Set
this Brivis Networker’s address!” If this message does not appear please repeat the resetting procedure.
• Now the parameter value can be set to “1” by rotating the dial, which will make this Brivis Networker a Master.
• Push the on/off button to exit.
13.2 Brivis Programmable and Brivis Manual Thermostat Installation
Brivis Programmable and Brivis Manual Thermostats can be wired directly to a StarPro Max/Plus or Classic heater.
Wiring the Brivis Programmable Thermostat (Part No. B019873)
• Run the appropriate wiring from the heater to the Thermostat.
• Remove the backing plate from the Thermostat. Draw the wires from the wall cavity and feed them through the
centre opening of the backing plate. Then mount the backing plate on the wall before making the wiring
connections.
• Connect terminals R and W on the heater to terminals R and W on the Thermostat.
• For fan only operation - Connect terminal G on the heater to terminal G at the Thermostat. This will allow for
fan only operation to circulate air through the house.
• Insert batteries and mount Thermostat onto the backing plate.
•
Refer to the Installation Guide and Operating Manual supplied with the Brivis Programmable Thermostat.
Wiring the Brivis Manual Thermostat (Part No. B022880)
• For manual Thermostats remove the front cover and mount the Thermostat in a suitable position, following the
instructions supplied with the control. Ensure the batteries are correctly installed.
• Make wiring connections (see diagram), then mount level on the wall before replacing the front cover.
• Connect terminals R and W at the heater to terminals A and B on the Thermostat.
• For fan only operation - Wire a switch in circuit between the R and G terminals at the heater.
• Refer to the Installation Guide supplied with the Manual Thermostat.
Note:
All Brivis Networkers come configured as Masters by default. Two Masters cannot be connected to one
system otherwise the system will not function properly. Also if both Brivis Networkers are set as Slaves, the Brivis
Networkers will lock out and will not be accessible.
Brivis Programmable
Thermostat
Brivis Programmable
Thermostat
18
W
R
W
R
CAAB021918I Installer's Heat_CAAB021918I 4/10/13 1:22 PM Page 21