Fault Finding

Before starting any work on the pump please ensure the 
electricity supply is turned off and cannot be accidentally 
switched back on at any time

Fault                Control Panel                Cause                Remedy             

Pump doesn’t 

run at all

 

Light is off

A) One fuse is 

blown 

Replace fuse

B) The current/

voltage operated 

circuit breaker 

has tripped out 

Cut in the 

circuit break

C) The Pump is 

defective

Replace Pump

Only shows power

A) Failure of 

electricity supply,

might be too low 

Check the 

supply falls 

within the 

specified range

Noise in the 

system

Light on for power 

and pump settings

A) Air in the 

system

Vent the 

system
Reduce the 

suction head

Noise in the 

Pump

Light on for power 

and pump settings

A) Air in Pump

Let the Pump 

run, it vents 

itself over time

Increase the inlet 

pressure. Check 

the air volume in 

the expansion 

tank if installed 

B) Inlet pressure 

is too low

Light on for power 

and pump setting

A) Pump 

perfomance is 

too low

Increase the 

suction head

Insufficient

B) The flow is 

too high

Summary of Contents for Domestic Pro

Page 1: ...Installation Operating Instructions Please read these instructions carefully before installation DP15 ...

Page 2: ...General Information 3 Pump Liquid Operating Conditions 4 Pump Diagram 5 Installation 6 Gaskets 7 Venting 8 Control Panel 9 Pressure Curve 10 Operating Modes 11 Fault Finding 12 Guarantees 13 Contents ...

Page 3: ...ctly suited to operate in Single zone heating systems Multi zone heating systems Underfloor heating systems The Pump incorporates a permanent magnet motor with differential pressure control which enables its performance to be aligned with actual system demand It has a connection size of 1 a maximum head of 6 metres and a port to port distance of 130mm making it perfect for domestic applications ...

Page 4: ...vent damage to their internal components The liquids used must not contain any solid Liquids running through circulation pumps used on heating systems must comply with the accepted standards of quality especially in domestic applications Liquids that do not comply will void the warranty offered with the circulation Pump ...

Page 5: ...Pump Diagram ...

Page 6: ...Installation Attention Ensure the Pump is installed with the motor shaft in the horizontal position ...

Page 7: ...Attention The Pump liquid may be scalding hot and under pressure Before removing head screws the system either requires draining or the Pump needs to be isolated ...

Page 8: ...Gaskets Attention Fit the two gaskets when the Pump is mounted correctly between the flow and return pipes ...

Page 9: ...Venting ...

Page 10: ...Attention The Pump liquid may be scalding hot and under pressure so proceed with caution when bleeding the Pump ...

Page 11: ...tion 4 Middle manual speed option 5 Highest manual speed option 6 Light field indicating NIGHT mode 7 Button for selecting NIGHT mode 8 Button for selecting each pump setting 9 CP1 Min constant pressure curve 10 CP2 Max constant pressure curve 11 PP1 Min proportion pressure curve 12 PP2 Max proportion pressure curve Control Panel ...

Page 12: ...Pressure Curve ...

Page 13: ...g PP1 Proportional Pressure 1 the duty point moves up down on the lowest proportional pressure curve Head pressure is then reduced and increased at falling and rising heating demand respectively PP2 Proportional Pressure 2 the duty point moves up down on thehighest proportional pressure curve Head pressure is then reduced and increased at falling and rising heating demand respectively CP1 Constant...

Page 14: ...p Only shows power A Failure of electricity supply might be too low Check the supply falls within the specified range Noise in the system Light on for power and pump settings A Air in the system Vent the system Reduce the suction head Noise in the Pump Light on for power and pump settings A Air in Pump Let the Pump run it vents itself over time Increase the inlet pressure Check the air volume in t...

Page 15: ...stered within 30 days of purchase The Pump is covered for a free of charge replacement should malfunction occur within the first 3 years from the date of sale From 3 years and up to 6 years the Pump is covered for a replacement at 50 of the original sale price To register go to www BritTherm co uk and click Register a Guarantee You will need Date of purchase Address where pump is fitted Name of su...

Reviews: