1. PHASE INDICATORS:
used to check if all 3 phases are available.
Important note: DO NOT operate the hoists if one of the phases is not present!
2. GENERAL CIRCUIT BREAKER:
protects ALL outputs, including the 32A output to the next unit. In case
of emergency all 3 phases AND the neutral are disconnected.
3. CONTROL CIRCUIT BREAKER:
protects the control electronics, should be switched on at all times to
ensure proper operation.
4. AUX OUTPUT CIRCUIT BREAKER:
protects the auxiliary mains output (15)
5. ON INDICATOR:
indicates that the unit (control electronics) is switched on and ready to be operated.
6. SLAVE INDICATOR:
is lit when the unit is used as slave unit, [LINK IN] connector (17) is used. The
[UP/DOWN] controls can only be operated from the master unit. The [EMERGENCY STOP] controls are
still operational on ALL connected controllers.
7. REMOTE INDICATOR:
is lit when the [RICO-REMOTE] controller is connected to the [REMOTE
CONTROL INPUT] (18). The [UP/DOWN] controls can only be operated from the remote controller. The
[EMERGENCY STOP] controls are still operational on ALL connected controllers.
8. MOTOR SWITCH:
used to select the operation mode of the connected motor:
•
POSITION 0: motor not used.
•
POSITION 1: motor connected with normal phase order (normal operation)
•
POSITION 2: motor connected with 2 phases switched (UP/DOWN inversed)
Important note: NEVER use these switches while the connected motor is running.
9. [UP/DOWN] BUTTONS:
as long as these buttons are pushed, the connected hoists will move in the
indicated direction. These buttons are only operational on units working as master.
10. [EMERGENCY STOP] BUTTON:
In case of an emergency you can press the [EMERGENCY STOP]
button on ANY of the controllers that are connected in master/slave mode: ALL motor outputs will
become inactive. The emergency button that was pressed lights up. To release (reset) it, rotate the
[EMERGENCY STOP] button clockwise.
11. SURFACE FOR NOTES:
can be used to write the exact function of the connected chain hoist motor.
FUNCTIONS
(REAR)