Briteq RICO-V4 Operation Manual Download Page 5

ENGLISH 

 

OPERATION MANUAL 

 

 
BRITEQ

®

 

3/6 

RICO-V4 

FUNCTIONS

 (FRONT) 

 

 

1.  PHASE INDICATORS:

 used to check if all 3 phases are available.  

Important note: DO NOT operate the hoists if one of the phases is not present! 

2.  GENERAL CIRCUIT BREAKER: 

protects ALL outputs, including the 32A output to the next unit. In case 

of emergency all 3 phases AND the neutral are disconnected.  

3.  CONTROL CIRCUIT BREAKER:

 protects the control electronics, should be switched on at all times to 

ensure proper operation.  

4.  AUX OUTPUT CIRCUIT BREAKER:

 protects the auxiliary mains output (15) 

5.  ON INDICATOR:

 indicates that the unit (control electronics) is switched on and ready to be operated. 

6.  SLAVE  INDICATOR:

  is  lit  when  the  unit  is  used  as  slave  unit,  [LINK  IN]  connector  (17)  is  used.  The 

[UP/DOWN] controls can only be operated from the master unit. The [EMERGENCY STOP] controls are 
still operational on ALL connected controllers. 

7.  REMOTE  INDICATOR:

  is  lit  when  the  [RICO-REMOTE]  controller  is  connected  to  the  [REMOTE 

CONTROL INPUT] (18). The [UP/DOWN] controls can only be operated from the remote controller. The 
[EMERGENCY STOP] controls are still operational on ALL connected controllers. 

8.  MOTOR SWITCH:

 used to select the operation mode of the connected motor: 

  POSITION 0:  motor not used. 

  POSITION 1:  motor connected with normal phase order (normal operation) 

  POSITION 2:  motor connected with 2 phases switched (UP/DOWN inversed) 

Important note: NEVER use these switches while the connected motor is running. 

9.  [UP/DOWN]  BUTTONS:

  as  long  as  these  buttons  are  pushed,  the  connected  hoists  will  move  in  the 

indicated direction. These buttons are only operational on units working as master.

 

10.  [EMERGENCY  STOP]  BUTTON:

  In  case  of  an  emergency  you  can  press  the  [EMERGENCY  STOP] 

button  on  ANY  of  the  controllers  that  are  connected  in  master/slave  mode:  ALL  motor  outputs  will 
become  inactive.  The  emergency  button  that  was  pressed  lights  up.  To  release  (reset)  it,  rotate  the 
[EMERGENCY STOP] button clockwise. 

11.  SURFACE FOR NOTES:

 can be used to write the exact function of the connected chain hoist motor.

 

 

FUNCTIONS

 (REAR) 

 

 