ENGLISH
USER MANUAL
BRITEQ
®
4/30
PD-63SH
F. 63A OUTPUT:
CEE (3P+N+E) outlet socket (3x 63A, 5wire), can be used to feed-through up to 63A
3phase current. Make sure that the total input current will not be exceeded!
G. 16A OUTPUTS: Each output has its individual circuit breaker (C) on the front panel
Output 1:
230V/16A output socket connected to phase1 (L1) and protected by breaker 1 (C)
Output 2:
230V/16A output socket connected to phase2 (L2) and protected by breaker 2 (C)
Output 3:
230V/16A output socket connected to phase3 (L3) and protected by breaker 3 (C)
Output 4:
230V/16A output socket connected to phase1 (L1) and protected by breaker 4 (C)
Output 5:
230V/16A output socket connected to phase2 (L2) and protected by breaker 5 (C)
Output 6:
230V/16A output socket connected to phase3 (L3) and protected by breaker 6 (C)
Output 7:
230V/16A output socket connected to phase1 (L1) and protected by breaker 7 (C)
Output 8:
230V/16A output socket connected to phase2 (L2) and protected by breaker 8 (C)
Output 9:
230V/16A output socket connected to phase3 (L3) and protected by breaker 9 (C)
Output 10:
230V/16A output socket connected to phase1 (L1) and protected by breaker 10 (C)
Output 11:
230V/16A output socket connected to phase2 (L2) and protected by breaker 11 (C)
Output 12:
230V/16A output socket connected to phase3 (L3) and protected by breaker 12 (C)
H. Ground Connection of the housing
I.
16-pin connectors:
for
use with “Harting” multicables.
J. Round 19-pin connectors:
for