![Briteq COB BLINDER 2x1000W Operation Manual Download Page 5](http://html.mh-extra.com/html/briteq/cob-blinder-2x1000w/cob-blinder-2x1000w_operation-manual_2814418005.webp)
ENGLISH
USER MANUAL
BRITEQ
®
3/41
COB BLINDER 2X100W
DESCRIPTION:
1. BRACKET:
with knobs on both sides to fasten the unit and a mounting hole to fix a mounting hook.
2. Mains input:
equipped with a Neutrik Powercon mains input connector.
3. Mains output:
equipped with a Neutrik Powercon mains output connector. You can use this output to
feed your next projectors.
(TOTAL LOAD = MAX. 16A !!!)
4. Fuse holder:
always replace a damaged fuse with a fuse of the same type and electrical specifications!
5. MODE (Menu) button:
used to browse the different functions in the menu
6. ENTER button:
used to confirm your choice or to enter the setup mode of a function.
7. UP button:
to increase the values shown on the display.
8. DOWN button:
to lower the values shown on the display.
9. DMX OUTPUT:
use the 3pin or 5pin female XLR-connector to connect the projector with the next unit in
the DMX chain.
10. DMX INPUT:
use the 3pin or 5pin female XLR-connector to connect the projector with the DMX
controller or with the previous unit in the DMX chain.
11. DISPLAY
shows the various menus and the selected functions.
OVERHEAD RIGGING
Important:
The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
Before rigging make sure that the installation
area can hold a minimum point load of 10times the device’s
weight.
Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
Don’t cover any ventilation openings as this may result in overheating.
The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.