ENGLISH
OPERATION MANUAL
BRITEQ
®
7/9
BT-PROFILE HD
51-60
AUTO 2
61-70
AUTO 3
71-80
AUTO 4
81-90
AUTO 5
91-100
AUTO 6
101-110
AUTO 7
111-120
AUTO 8
121-130
AUTO 9
131-140
AUTO 10
141-150
PROGRAM 1
151-160
PROGRAM 2
161-255
No function
--
--
10
16
8
Auto speed
0-255
Slow to fast
--
7
11
17
6
9
Shutter
000-009
Open
010-099
Strobe (0-25Hz)
100-109
Open
110-179
THUNDER STROBE
180-189
Open
190-255
Random Strobe
--
--
12
18
7
10
Control
000-060
No function
061-070
Fan mode = Live *
071-080
Fan mode = Studio *
081-090
Fan mode = Power *
091-100
Reserved
101-110
Dimmer speed off *
111-120
Dimmer speed Dim4 *
121-150
Reserved
151-160
PWM = 1200Hz *
161-170
PWM = 2400Hz *
171-180
PWM = 4000Hz *
181-190
PWM = 6000Hz *
191-200
PWM = 25000Hz *
201-210
All reset *
211-255
Reserved
*Function will be activated after 3s
MAINTENANCE
•
Make sure the area below the installation place is free from unwanted persons during servicing.
•
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
•
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
•
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
•
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
•
The mains cables must be in impeccable condition and should be replaced immediately when even a small
problem is detected.
•
In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
•
The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
•
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize
light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or
particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics.
•
Clean with a soft cloth using normal glass cleaning products.
•
Always dry the parts carefully.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!