Brita BPF89CATCB100TOC Installation Manual Download Page 6

6

COMPONENTS &

SPECIFICATIONS

Working Temperature = 34-110°F 

(1-43°C)

(Do not subject the unit to freezing 

temperatures)

Working Pressure = 30-125 PSIG 

(137-861 kPa)

Voltage = 120V / 60 Hz

Pipe Size = 3/4” and 1”

•  At the stated service flow rates, the 

pressure drop through these devices 

will not exceed 15 psig.

•  The manufacturer reserves the right 

to make product improvements which 

may deviate from the specifications 

and descriptions stated herein, 

without obligation to change previously 

manufactured products or to note the 

change.

*  Do not use water that is 

microbiologically unsafe without 

adequate disinfection before or after 

the system. 

Peak flow rates intended for intermittent 

use only (10 minutes or less) and are 

for residential applications only. Do 

not use peak flow rate for commercial 

applications or for a continuous 

rate when treated water supplies are 

geothermal heat pump, swimming 

pool, etc.

For satisfactory operation, the pumping 

rate of the well system must equal or 

exceed indicated backwash flow rate.

All units come with plastic bypass. 

TASTE & ODOR (COCONUT SHELL CARBON) FILTERS

Platinum Series

Media Cu 

Ft

Flow Rate USGPM

Mineral 

Tank Size

Pipe Size 

Inches

Ship Weight 

Lbs

Service

Peak

Backwash

BPF89CB75TO

0.75

4.0

5.0

3.5

8 x 44

3/4” - 1”

50

BPF89CB100TO

1.00

5.0

7.0

4.0

9 x 48

3/4” - 1”

60

BPF89CB150TO

1.50

7.0

10.0

5.0

10 x 54

3/4” - 1”

78

BPF89CB200TO

2.00

10.0

12.0

7.0

12 x 52

3/4” - 1”

95

BPF89CB300TO

3.00

12.0

15.0

10.0

14 x 65

3/4” - 1”

138

TASTE & ODOR (COCONUT SHELL CARBON) FILTERS W/KDF 

Platinum Series

Media Cu 

Ft

Flow Rate USGPM

Mineral 

Tank Size

Pipe Size 

Inches

Ship Weight 

Lbs

Service

Peak

Backwash

BPF89CBK75TOK

0.75

4.0

5.0

3.5

8 x 44

3/4” - 1”

50

BPF89CBK100TOK

1.00

5.0

7.0

4.0

9 x 48

3/4” - 1”

60

BPF89CBK150TOK

1.50

7.0

10.0

5.0

10 x 54

3/4” - 1”

78

BPF89CBK200TOK

2.00

10.0

12.0

7.0

12 x 52

3/4” - 1”

95

BPF89CBK300TOK

3.00

12.0

15.0

10.0

14 x 65

3/4” - 1”

138

CATALYTIC CARBON FILTERS (CHLORAMINES REDUCTION)

Platinum Series

Media Cu 

Ft

Flow Rate USGPM

Mineral 

Tank Size

Pipe Size 

Inches

Ship Weight 

Lbs

Service

Peak

Backwash

BPF89CATCB75TOC

0.75

4.0

5.0

3.5

8 x 44

3/4” - 1”

50

BPF89CATCB100TOC

1.00

5.0

7.0

4.0

9 x 48

3/4” - 1”

60

BPF89CATCB150TOC

1.50

7.0

10.0

5.0

10 x 54

3/4” - 1”

78

BPF89CATCB200TOC

2.00

10.0

12.0

7.0

12 x 52

3/4” - 1”

95

BPF89CATCB300TOC

3.00

12.0

15.0

10.0

14 x 65

3/4” - 1”

138

CATALYTIC CARBON FILTERS (CHLORAMINES REDUCTION) W/ KDF

Platinum Series

Media Cu 

Ft

Flow Rate USGPM

Mineral 

Tank Size

Pipe Size 

Inches

Ship Weight 

Lbs

Service

Peak

Backwash

BPF89CATCBK75TOCK

0.75

4.0

5.0

3.5

8 x 44

3/4” - 1”

50

BPF89CATCBK100TOCK

1.00

5.0

7.0

4.0

9 x 48

3/4” - 1”

60

BPF89CATCBK150TOCK

1.50

7.0

10.0

5.0

10 x 54

3/4” - 1”

78

BPF89CATCBK200TOCK

2.00

10.0

12.0

7.0

12 x 52

3/4” - 1”

95

BPF89CATCBK300TOCK

3.00

12.0

15.0

10.0

14 x 65

3/4” - 1”

138

NEUTRALIZING FILTERS

Platinum Series

Media Cu 

Ft

Flow Rate USGPM

Mineral 

Tank Size

Pipe Size 

Inches

Ship Weight 

Lbs

Service

Peak

Backwash

BPF89NEU75PH

0.75

2.0

3.5

3.5

8 x 44

3/4” - 1”

93

BPF89NEU100PH

1.00

3.0

5.0

4.0

9 x 48

3/4” - 1”

120

BPF89NEU150PH

1.50

5.0

8.0

5.0

10 x 54

3/4” - 1”

164

BPF89NEU200PH

2.00

6.0

10.0

7.0

12 x 52

3/4” - 1”

207

BPF89NEU300PH

3.00

7.0

12.0

10.0

14 x 65

3/4” - 1”

330

NEXSAND PARTICULATE FILTERS

Platinum Series

Media Cu 

Ft

Flow Rate USGPM

Micron 

Rating

Mineral 

Tank Size

Pipe Size 

Inches

Ship 

Weight 

Lbs

Service

Peak

Backwash

BPF89NEX75TUR

0.75

4.0

6.0

5.0

 3 - 5 µ 

8 x 44

3/4” - 1”

90

BPF89NEX100TUR

1.00

5.0

8.0

7.0

 3 - 5 µ 

9 x 48

3/4” - 1”

135

BPF89NEX150TUR

1.50

8.0

10.0

10.0

 3 - 5 µ 

10 x 54

3/4” - 1”

205

BPF89NEX200TUR

2.00

10.0

12.0

14.0

 3 - 5 µ 

12 x 52

3/4” - 1”

255

Summary of Contents for BPF89CATCB100TOC

Page 1: ...MANUAL Professional Installation Version V1 0F 54565 PLATINUM TASTE AND ODOR TO MULTIMEDIA MM NEXSAND NEUTRALIZER NU BIRM BM FILTER...

Page 2: ...of Brita LP and are used under license by Protect Plus LLC All rights reserved The Platinum Carbon Filter Series is certified by IAPMO R T to NSF ANSI 42 for chlorine taste and odor reduction The Plat...

Page 3: ...M CLEANUP 21 SOFTENER WATER BYPASS OPERATING CONDITIONS 22 MAINTENANCE INSTRUCTIONS 23 BACKWASHING INSTRUCTIONS 24 CALCULATE BACKWASH FREQUENCY 24 SERVICE THE PLATINUM VALVE 24 PROGRAMMING MASTER PROG...

Page 4: ...damaged o rings during installation Softeners are exposed to high levels of iron manganese sulfur and sediments Damage to pistons seals and or spacers within the control valve are not covered in this...

Page 5: ...hrough the 10 micron filter paper has unacceptable quality a MMF filter might not be applicable As a guide the U S Public Health Drinking Water standards states the turbidity should not exceed 1 NTU T...

Page 6: ...4 1 50 BPF89CBK100TOK 1 00 5 0 7 0 4 0 9 x 48 3 4 1 60 BPF89CBK150TOK 1 50 7 0 10 0 5 0 10 x 54 3 4 1 78 BPF89CBK200TOK 2 00 10 0 12 0 7 0 12 x 52 3 4 1 95 BPF89CBK300TOK 3 00 12 0 15 0 10 0 14 x 65 3...

Page 7: ...ON The unit then returns to the In Service position While this happens water continues to enter the tank Step1 Step 2 Step 3 Step1 Step 2 Step 3 Models Backwash Minutes Rapid Rinse Minutes Total Time...

Page 8: ...were purchased UNPACK INSPECT PLATINUM FILTER 3 PARTS BOX INSTALLATION Check the entire unit for any shipping damage or lost parts Note any damage to the shipping cartons Contact the transportation co...

Page 9: ...L VALVE Distributor Tube Inside the Tank Media Inside the Tank Media Type will depend on what models were purchased FOR MODELS 200 300 THE MEDIA AND CONTROL VALVE IS PACKAGED SEPARATELY IN CARTON AND...

Page 10: ...f Manufacture of complete system Both Serial labels are important for troubleshooting VALVE SERIAL NUMBER COMPLETE SYSTEM SERIAL NUMBER 22018448W Part L YEAR N stand for 2017 year M stand for 2016 yea...

Page 11: ...lines If these lines are cut during installation of the Noryl bypass valve and or poly pipe an approved grounding strap must be used between the two lines that have been cut This will maintain contin...

Page 12: ...r Hard Soft Water Water Heater Softener Drain Taste and Odor TO Filter Multi Media Filter MM or nextSand Ground Strap Water Meter Raw Water To Outdoors Drain Electrical Panel Hard Filtered Water Cold...

Page 13: ...INSTALLATION Hard Filtered Water Cold Soft Water Hard Soft Water Water Heater Softener Drain Taste and Odor TO Filter Multi Media Filter NU Ground Strap Water Meter Raw Water To Outdoors Drain Multi M...

Page 14: ...dry tub drain 3 Locate in correct relationship to other water conditioning equipment see Fig 1 on Page 10 4 Softener should be located in the supply line before the water heater Temperatures above 120...

Page 15: ...e connection or drain outlet shall be designed and constructed to provide an air gap to the sanitary waste system of 2 pipe diameters or 1 inch 22 mm whichever is larger The valves are labeled inlet a...

Page 16: ...lls down into the distribution The riser distributor remains inside the tank seated in the depression at the bottom Plug tube with a tape Remove after media is loaded C Fill support bed first The medi...

Page 17: ...ort Bed when supplied Fine Medium and or Coarse Gravel MULTI MEDIA FILTER MM OR NEXSAND MEDIA BED Nexsand Black Support Bed when supplied Fine Medium and or Coarse Gravel ACTIVATED CARBON FILTER ACF M...

Page 18: ...dia CAUTION Make sure that the unit is de pressurized before conducting this task DO NOT use petroleum based lubricants as they will cause swelling of O ring seals NOTE CAUTION Make sure the O Ring is...

Page 19: ...e pipe thread compound as it may attack the material in the valve body Make sure both brass and plastic nuts are tightened well 3 MEDIA INSTALLATION Inspect and check that the brine line plug is conne...

Page 20: ...NU SET These buttons increase or decrease the value of the settings while in the programming mode This function enters the basic set up information required at the time of installation KEY PAD CONFIGU...

Page 21: ...ked when originally sizing the system If a high demand situation exists resize the system using continuous service flow rate data DURING REGENERATION AUTOMATIC BYPASS The regeneration cycle lasts appr...

Page 22: ...has been exposed to both iron and hardness for a long period of time replacement of the heater tank may be the only practical solution to prevent continued staining originating from this source TOILET...

Page 23: ...pending on the inlet water quality and water usage The media should be replenished or replaced depending of inlet water quality and water consumption Check with your water treatment expert on the medi...

Page 24: ...r A If the conditioner installation has a 3 valve bypass system first open the valve in the bypass line then close the valves at the conditioner inlet outlet B If the conditioner has an integral bypas...

Page 25: ...GALLONS FILTER 1 364 DONT TOUCH OFF DAYS 10 10 12 00AM 3 DAYS 1 White 0 4 0 3S NU 150 ENGLISH US GALLONS FILTER 1 364 DONT TOUCH OFF DAYS 10 10 12 00AM 3 DAYS 1 White 0 5 0 4S NU 200 ENGLISH US GALLO...

Page 26: ...l Setup interface n Language n Region n Valve n Meter Ratio n Salt vs Efficiency Setting n Calculation Initial Setup interface n Language n Region n Valve n Meter Ratio n Salt vs Efficiency Setting n...

Page 27: ...HistoryValues General Diagnostics Reserve Usage History Usage History 28 Days History History Since Startup History Since Reset Usage History 28 Days History History Since Startup History Since Reset...

Page 28: ...ce the piston assembly and reverse following steps in this section CLEAN INJECTOR ASSEMBLY 1 Remove the two screws from the injector cap 2 Pull the injector cap and gasket 3 Pull the injector assembly...

Page 29: ...from the valve body assembly 7 Replace the powerhead by reverse following the steps in this section Piston Screw 2 X Screws from Powerhead Washer Powerhead Assembly Valve Body Assembly REPLACE MOTOR 1...

Page 30: ...ss by removing clips 3 Remove the coupling adaptor from the valve 4 Remove the meter support and then the impeller out from the coupling and clean it 5 Replace meter with the help of special tool and...

Page 31: ...is returned to the In Service position AFTER SERVICING 1 Remove the screws from the back of the valve and pull the front cover 2 Remove all connections from the circuit board 3 Remove the four screws...

Page 32: ...ne Washer 1 Pull the drain line clip and remove the drain line elbow and washer 2 Clean replace drain line washer REPLACE DRAIN LINE FLOW CONTROL 1 Pull the brine line clip and remove the brine line e...

Page 33: ...43 95418 MM 100 9 x 48 25010034 25010036 25010035 50010005 10010043 95415 MM 150 10 x 54 25010049 25010051 25010050 50010005 10010043 95416 MM 200 12 x 52 25010058 25010060 25010059 50010005 10010043...

Page 34: ...89 Drive Gear 1 B16 DNR Screw on Back Cover 4 B15 DNR Washers on Screw 4 B14 DNR Platinum Back Cover 1 B13 92392 Brine Gear 1 B12 60010577 Locating wheel UF 1 B11 60010661 Washer on Locating Wheel 1 B...

Page 35: ...2 C11 60010069 Secure Clip of Plug 2 C10 92387 Secure Clip Inlet and Oulet 2 C9 DNR Steel Retainer Ring 2 C8 60010252 Elbow 1 NPT Inlet and Oulet 2 C7 60010592 Straight 1 NPT Inlet and Oulet 2 C6 600...

Page 36: ...ing of Injector Holder 1 A29 DNR Platinum Valve Body 1 A28 60010069 Secure Clip Brine Line 1 A27 DNR End Plug Retainer 1 A26 60010076 Valve Body Connect Screws 2 A25 60010075 End Plug Retainer Screws...

Page 37: ...1 12 60010612 INJECTOR NOZZLE BLUE 2 1 13 60010613 INJECTOR THROAT YELLOW 3 1 14 60010614 INJECTOR NOZZLE YELLOW 3 1 1 60095720 BNT95DLFC 0 4 0 GPM 1 2 60010143 BNT95DLFC 1 7 0GPM 1 3 60010144 BNT95DL...

Page 38: ...does not run A Assure permanent electrical service check fuse plug or switch B Replace timer C Reset time of day D Replace defective motor 3 FILTER REGENERATES EVERY DAY A Faulty gear train A Check th...

Page 39: ...39 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 40: ...40 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 41: ...equal to the permissible limit for the water leaving the system as specified in NSF ANSI Standard 42 Please see warranty for manufacturer s limited warranty Please see installation instructions for in...

Page 42: ...than or equal to the permissible limit for the water leaving the system as specified in NSF ANSI Standard 42 Please see warranty for manufacturer s limited warranty Please see installation instruction...

Page 43: ...less than or equal to the permissible limit for the water leaving the system as specified in NSF ANSI Standard 42 Please see warranty for manufacturer s limited warranty Please see installation instru...

Page 44: ...tion less than or equal to the permissible limit for the water leaving the system as specified in NSF ANSI Standard 42 Please see warranty for manufacturer s limited warranty Please see installation i...

Page 45: ...ntration less than or equal to the permissible limit for the water leaving the system as specified in NSF ANSI Standard 42 Please see warranty for manufacturer s limited warranty Please see installati...

Page 46: ...l to the permissible limit for the water leaving the system as specified in NSF ANSI Standard 42 Please see warranty for manufacturer s limited warranty Please see installation instructions for intern...

Page 47: ...placement mineral tank or brine tank to any approved dealer that purchased the new water conditioner assembled unit from Protect Plus Pro LLC and whose client is in possession of a tank that fails pro...

Page 48: ...erated The new water conditioner assembled unit consists of a control valve pressure tank and brine tank sold as a complete assembled unit For component parts not sold as a new water conditioner assem...

Reviews: