Brita BPF89CATCB100TOC Installation Manual Download Page 23

23

1.  Verify the pumping rate of the system - do not refer to a 

pumping curve for this data. Follow the instructions found 

on page 7. If the measured pumping rate is less than the 

backwash rate of the filter, see page 39, Trouble Shooting.

2.  Have your water tested - for pH, iron and manganese on both 

the treated and raw water to ensure your water conditions 

haven’t changed.

3.   Inspect the Control Valve and the piping between the iron filter 

and the pressure tank to ensure they are not plugged with 

raw iron. If the line becomes plugged, the flow of water to the 

home will be reduced. This will result in a reduction of water 

available for backwashing the unit which will inhibit operation 

of the system.

4.  Air-to-water pressure tank - periodically drain and flush your 

tank to prevent a build-up of precipitated iron from forming in 

the bottom of the tank.

5.  Bladder tank - periodically check that the bladder air pressure 

remains at 2 psi lower than the cut-in pressure of your pump.

6.  For applications with low pH, manganese or hydrogen sulfide, 

consult your local dealer for specific instructions to maintain 

the efficiency and operation of your filter.

7.  Periodic cleaning of the air vent assembly with mild acid 

or vinegar will ensure that it continues to vent excess air 

properly.

8.  The filter tank can be cleaned with a mild soap solution.

9.  Never subject the unit to freezing

CARE OF YOUR FILTER

 

To retain the attractive appearance of your new water filter, 

clean occasionally with a mild soap solution. Do not use abrasive 

cleaners, ammonia or solvents. Never subject your filter to 

freezing or to temperatures above 43°C (110°F).

SERVICING COMPONENTS

-  

  The seals and cartridge should be inspected/cleaned or 

replaced every year depending on the inlet water quality 

  and water usage.

  The media should be replenished or replaced depending 

of inlet water quality and water consumption. Check with 

your water treatment expert on the media bed change 

frequency.  

BELOW ARE SOME GUIDELINES:

  Piston assembly, seal and spacers, injectors should be 

replaced on an annual basis.

  Please refer to the servicing section of this manual for step by 

step procedure.

  Not following the above will void all warranty on the control 

valve.

  Maintenance of your new water filter requires very little time 

or effort but it is essential. Regular maintenance will ensure 

many years of efficient and trouble free operation.

 

REPLACING MEDIA BED

The media bed in a neutralizing Model NU  filter is slowly 

dissolved and has to be replaced. The frequency of replacement 

varies, depending on water quality - consult your dealer to 

determine the expected life of your media bed.

NU - the media bed in a neutralizing filter is slowly dissolved 

and has to be replaced. The frequency of replacement varies, 

depending on water quality - consult your dealer to determine 

the expected life of your media bed.

TO - under normal operating conditions the effective life of the 

filter media is approximately one to three years depending 

on the water quality, after which, taste and odor problems 

may return. When this happens contact your dealer for a 

replacement media bed.

MM / Nexsand - under normal operating conditions, the media 

should never need to be replaced. If you experience pressure 

loss and cannot correct it with a manual regeneration, your 

media bed may need replacing - contact your dealer.

BM - Depending on the raw water iron content.

Maintenance Kit 

(60010307) 

MAINTENANCE INSTRUCTIONS 

  Your chem free iron filter requires some minor maintenance to ensure optimum 

performance and years of trouble-free clean water. The following steps should be 

performed once or twice a year (more often under harsh conditions):

Summary of Contents for BPF89CATCB100TOC

Page 1: ...MANUAL Professional Installation Version V1 0F 54565 PLATINUM TASTE AND ODOR TO MULTIMEDIA MM NEXSAND NEUTRALIZER NU BIRM BM FILTER...

Page 2: ...of Brita LP and are used under license by Protect Plus LLC All rights reserved The Platinum Carbon Filter Series is certified by IAPMO R T to NSF ANSI 42 for chlorine taste and odor reduction The Plat...

Page 3: ...M CLEANUP 21 SOFTENER WATER BYPASS OPERATING CONDITIONS 22 MAINTENANCE INSTRUCTIONS 23 BACKWASHING INSTRUCTIONS 24 CALCULATE BACKWASH FREQUENCY 24 SERVICE THE PLATINUM VALVE 24 PROGRAMMING MASTER PROG...

Page 4: ...damaged o rings during installation Softeners are exposed to high levels of iron manganese sulfur and sediments Damage to pistons seals and or spacers within the control valve are not covered in this...

Page 5: ...hrough the 10 micron filter paper has unacceptable quality a MMF filter might not be applicable As a guide the U S Public Health Drinking Water standards states the turbidity should not exceed 1 NTU T...

Page 6: ...4 1 50 BPF89CBK100TOK 1 00 5 0 7 0 4 0 9 x 48 3 4 1 60 BPF89CBK150TOK 1 50 7 0 10 0 5 0 10 x 54 3 4 1 78 BPF89CBK200TOK 2 00 10 0 12 0 7 0 12 x 52 3 4 1 95 BPF89CBK300TOK 3 00 12 0 15 0 10 0 14 x 65 3...

Page 7: ...ON The unit then returns to the In Service position While this happens water continues to enter the tank Step1 Step 2 Step 3 Step1 Step 2 Step 3 Models Backwash Minutes Rapid Rinse Minutes Total Time...

Page 8: ...were purchased UNPACK INSPECT PLATINUM FILTER 3 PARTS BOX INSTALLATION Check the entire unit for any shipping damage or lost parts Note any damage to the shipping cartons Contact the transportation co...

Page 9: ...L VALVE Distributor Tube Inside the Tank Media Inside the Tank Media Type will depend on what models were purchased FOR MODELS 200 300 THE MEDIA AND CONTROL VALVE IS PACKAGED SEPARATELY IN CARTON AND...

Page 10: ...f Manufacture of complete system Both Serial labels are important for troubleshooting VALVE SERIAL NUMBER COMPLETE SYSTEM SERIAL NUMBER 22018448W Part L YEAR N stand for 2017 year M stand for 2016 yea...

Page 11: ...lines If these lines are cut during installation of the Noryl bypass valve and or poly pipe an approved grounding strap must be used between the two lines that have been cut This will maintain contin...

Page 12: ...r Hard Soft Water Water Heater Softener Drain Taste and Odor TO Filter Multi Media Filter MM or nextSand Ground Strap Water Meter Raw Water To Outdoors Drain Electrical Panel Hard Filtered Water Cold...

Page 13: ...INSTALLATION Hard Filtered Water Cold Soft Water Hard Soft Water Water Heater Softener Drain Taste and Odor TO Filter Multi Media Filter NU Ground Strap Water Meter Raw Water To Outdoors Drain Multi M...

Page 14: ...dry tub drain 3 Locate in correct relationship to other water conditioning equipment see Fig 1 on Page 10 4 Softener should be located in the supply line before the water heater Temperatures above 120...

Page 15: ...e connection or drain outlet shall be designed and constructed to provide an air gap to the sanitary waste system of 2 pipe diameters or 1 inch 22 mm whichever is larger The valves are labeled inlet a...

Page 16: ...lls down into the distribution The riser distributor remains inside the tank seated in the depression at the bottom Plug tube with a tape Remove after media is loaded C Fill support bed first The medi...

Page 17: ...ort Bed when supplied Fine Medium and or Coarse Gravel MULTI MEDIA FILTER MM OR NEXSAND MEDIA BED Nexsand Black Support Bed when supplied Fine Medium and or Coarse Gravel ACTIVATED CARBON FILTER ACF M...

Page 18: ...dia CAUTION Make sure that the unit is de pressurized before conducting this task DO NOT use petroleum based lubricants as they will cause swelling of O ring seals NOTE CAUTION Make sure the O Ring is...

Page 19: ...e pipe thread compound as it may attack the material in the valve body Make sure both brass and plastic nuts are tightened well 3 MEDIA INSTALLATION Inspect and check that the brine line plug is conne...

Page 20: ...NU SET These buttons increase or decrease the value of the settings while in the programming mode This function enters the basic set up information required at the time of installation KEY PAD CONFIGU...

Page 21: ...ked when originally sizing the system If a high demand situation exists resize the system using continuous service flow rate data DURING REGENERATION AUTOMATIC BYPASS The regeneration cycle lasts appr...

Page 22: ...has been exposed to both iron and hardness for a long period of time replacement of the heater tank may be the only practical solution to prevent continued staining originating from this source TOILET...

Page 23: ...pending on the inlet water quality and water usage The media should be replenished or replaced depending of inlet water quality and water consumption Check with your water treatment expert on the medi...

Page 24: ...r A If the conditioner installation has a 3 valve bypass system first open the valve in the bypass line then close the valves at the conditioner inlet outlet B If the conditioner has an integral bypas...

Page 25: ...GALLONS FILTER 1 364 DONT TOUCH OFF DAYS 10 10 12 00AM 3 DAYS 1 White 0 4 0 3S NU 150 ENGLISH US GALLONS FILTER 1 364 DONT TOUCH OFF DAYS 10 10 12 00AM 3 DAYS 1 White 0 5 0 4S NU 200 ENGLISH US GALLO...

Page 26: ...l Setup interface n Language n Region n Valve n Meter Ratio n Salt vs Efficiency Setting n Calculation Initial Setup interface n Language n Region n Valve n Meter Ratio n Salt vs Efficiency Setting n...

Page 27: ...HistoryValues General Diagnostics Reserve Usage History Usage History 28 Days History History Since Startup History Since Reset Usage History 28 Days History History Since Startup History Since Reset...

Page 28: ...ce the piston assembly and reverse following steps in this section CLEAN INJECTOR ASSEMBLY 1 Remove the two screws from the injector cap 2 Pull the injector cap and gasket 3 Pull the injector assembly...

Page 29: ...from the valve body assembly 7 Replace the powerhead by reverse following the steps in this section Piston Screw 2 X Screws from Powerhead Washer Powerhead Assembly Valve Body Assembly REPLACE MOTOR 1...

Page 30: ...ss by removing clips 3 Remove the coupling adaptor from the valve 4 Remove the meter support and then the impeller out from the coupling and clean it 5 Replace meter with the help of special tool and...

Page 31: ...is returned to the In Service position AFTER SERVICING 1 Remove the screws from the back of the valve and pull the front cover 2 Remove all connections from the circuit board 3 Remove the four screws...

Page 32: ...ne Washer 1 Pull the drain line clip and remove the drain line elbow and washer 2 Clean replace drain line washer REPLACE DRAIN LINE FLOW CONTROL 1 Pull the brine line clip and remove the brine line e...

Page 33: ...43 95418 MM 100 9 x 48 25010034 25010036 25010035 50010005 10010043 95415 MM 150 10 x 54 25010049 25010051 25010050 50010005 10010043 95416 MM 200 12 x 52 25010058 25010060 25010059 50010005 10010043...

Page 34: ...89 Drive Gear 1 B16 DNR Screw on Back Cover 4 B15 DNR Washers on Screw 4 B14 DNR Platinum Back Cover 1 B13 92392 Brine Gear 1 B12 60010577 Locating wheel UF 1 B11 60010661 Washer on Locating Wheel 1 B...

Page 35: ...2 C11 60010069 Secure Clip of Plug 2 C10 92387 Secure Clip Inlet and Oulet 2 C9 DNR Steel Retainer Ring 2 C8 60010252 Elbow 1 NPT Inlet and Oulet 2 C7 60010592 Straight 1 NPT Inlet and Oulet 2 C6 600...

Page 36: ...ing of Injector Holder 1 A29 DNR Platinum Valve Body 1 A28 60010069 Secure Clip Brine Line 1 A27 DNR End Plug Retainer 1 A26 60010076 Valve Body Connect Screws 2 A25 60010075 End Plug Retainer Screws...

Page 37: ...1 12 60010612 INJECTOR NOZZLE BLUE 2 1 13 60010613 INJECTOR THROAT YELLOW 3 1 14 60010614 INJECTOR NOZZLE YELLOW 3 1 1 60095720 BNT95DLFC 0 4 0 GPM 1 2 60010143 BNT95DLFC 1 7 0GPM 1 3 60010144 BNT95DL...

Page 38: ...does not run A Assure permanent electrical service check fuse plug or switch B Replace timer C Reset time of day D Replace defective motor 3 FILTER REGENERATES EVERY DAY A Faulty gear train A Check th...

Page 39: ...39 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 40: ...40 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 41: ...equal to the permissible limit for the water leaving the system as specified in NSF ANSI Standard 42 Please see warranty for manufacturer s limited warranty Please see installation instructions for in...

Page 42: ...than or equal to the permissible limit for the water leaving the system as specified in NSF ANSI Standard 42 Please see warranty for manufacturer s limited warranty Please see installation instruction...

Page 43: ...less than or equal to the permissible limit for the water leaving the system as specified in NSF ANSI Standard 42 Please see warranty for manufacturer s limited warranty Please see installation instru...

Page 44: ...tion less than or equal to the permissible limit for the water leaving the system as specified in NSF ANSI Standard 42 Please see warranty for manufacturer s limited warranty Please see installation i...

Page 45: ...ntration less than or equal to the permissible limit for the water leaving the system as specified in NSF ANSI Standard 42 Please see warranty for manufacturer s limited warranty Please see installati...

Page 46: ...l to the permissible limit for the water leaving the system as specified in NSF ANSI Standard 42 Please see warranty for manufacturer s limited warranty Please see installation instructions for intern...

Page 47: ...placement mineral tank or brine tank to any approved dealer that purchased the new water conditioner assembled unit from Protect Plus Pro LLC and whose client is in possession of a tank that fails pro...

Page 48: ...erated The new water conditioner assembled unit consists of a control valve pressure tank and brine tank sold as a complete assembled unit For component parts not sold as a new water conditioner assem...

Reviews: