![Brita 3-Way Water Filter Dispenser System Instructions For Use Manual Download Page 9](http://html1.mh-extra.com/html/brita/3-way-water-filter-dispenser-system/3-way-water-filter-dispenser-system_instructions-for-use-manual_2813625009.webp)
8
ENGLISH
A
Attach the wall mount in place using the two matching screws
and use two wall plugs, if necessary, depending on the type of
wall.
B
Engage the fi lter head (2) in the wall mount (1). Please use the
fi xation holes (4).
3.7
Step 7: Commissioning
Before use, make sure that you have followed all the steps
correctly and all the parts are fi tted. Place a suitable container
under the cartridge to catch any leakages.
A
Turn on the cold and hot water supplies and check the system
carefully for any leaks.
B
Open the BRITA branded lever on your BRITA 3-Way Water
Filter Dispenser and rinse through until the fi ltered water runs
clear and without any bubbles (at least 2 litres).
4
Replacing the fi lter cartridge
The fi lter cartridge must be replaced when it runs out or at
latest 6 months after commissioning, irrespective of the level of
exhaustion of the fi lter system.
!
Read the Operating and Safety Information (chapter 9)
prior to exchange. After storage and transport below 0°C,
the product must be stored in the open original packaging
for at least 24 hours at the stated ambient temperatures
( chapter 7) for operation.
NOTE
The fi lter cartridge can be pivoted by 90° in the wall mount
for easy removal. When the locking handle is open, the
water supply to the cartridge is interrupted and by-passing
with direct water fl ow from the water inlet to the outlet is
possible.
Replacing the P 1000 (see fi g. 8):
A
Open the locking handle (3).
B
Place a suitable container under the fl ush hose to catch the rinse
water. Activate the fl ush valve (5) and release pressure from the
system.
C
Remove the exhausted fi lter cartridge (4) from the fi lter head (2) –
please be aware, the cartridge is fi rmly embedded so you can
give it a fi rm pull without worrying about breaking it.
D
Insert the new fi lter cartridge (see chapter 3.5).
E
Close the locking handle (3).
F
Reset the BRITA cartridge exchange indicator (chapter 5)
Replacing the P 3000 refi ll cartridge is exactly the same as
replacing the P 1000. The P 3000 lasts up to 6 months with the
++-setting and up to a year with the +-setting. Please take this
into consideration while resetting your BRITA cartridge exchange
indicator.
5
Resetting the BRITA electronic cartridge
exchange
indicator
If the maximum time or volume is reached, the BRITA electronic
cartridge exchange indicator will start beeping. (chapter 5)
– then the fi lter cartridge should be changed (chapter 4)
–
the BRITA electronic cartridge exchange indicator has to be
reset.
a) Press the DISPLAY button briefl y to activate the display.
b) Press and hold the START/RESET button for 5 seconds until a
long beep sounds.
c) The last programmed 90 or 180 day setting now appears in
the display.
d) The timer starts automatically.
6
Maintenance
Regularly check the fi lter system for leaks. Regularly check the
hoses for kinks. Bent hoses must be replaced.
!
Prior to exchanging the fi lter system, read the Technical
Data (chapter 7) and the Operating and Safety Information
(chapter 9).
Regularly clean the outside of the fi lter system with a soft, damp
cloth.
!
Do not use any abrasive chemicals, cleaning solutions or
astringent cleaning agents.