88
9
Fitting your Shower
COLD
L
N
E
Refit unit to pipes and secure to wall using 32mm x No. 8 screws
provided.
Connect the wire which may be coloured Brown or Red to the
terminal marked
L
. Connect the wire which may be coloured Black
or Blue to the terminal marked
N
. Connect the wire which may be
coloured Yellow/Green to the terminal marked
E
.
Secure into position with the cable clamp and tighten the two fixing
screws.
Do not fit the front cover at this stage refer to the commissioning
procedure.
Note: If the electrical supply cable is concealed in the wall ensure
that it avoids the unit’s fixing points so that fixing screws do not
pierce the cable.
HOT
COLD
Need help?
Give us a call on
0844 701 6273
and speak to one of our trained advisors.
Wall fixing points
Electrical connections
Cable Clamp
Cable Connector