15

Guarantee

Need help?

 Give us a call on

 0844 701 6273

 and speak to one of our trained advisors.  

Guarantee 

Thank you for purchasing a Bristan product. This product 

has been designed and tested, in the UK, to the highest 

standards.

Guarantee: 2 Year parts. 

  1 Year labour (subject to registration). 

This guarantee applies to products purchased within the 

United Kingdom or Republic of Ireland, but does not apply 

to products used commercially.

This is provided that:

1. The guarantee registration card is completed and 

returned within ten days complete with a copy of proof of 

purchase. Proof of purchase is required for any servicing 

requirements.

2. The product is installed and operated in accordance with 

our instructions and has not been misused or damaged.

This in no way affects your statutory rights as a consumer. 

The information on the Guarantee card helps Bristan to 

process any claims and contact you about your product 

and its maintenance if required. The registration of your 

personal details is purely for Bristan use and the remaining 

information helps us to make products for the future.

Should a complaint arise, products are guaranteed against 

faulty workmanship and materials for a period of 12 

months from the date of purchase, when in domestic use 

(second year guarantee is parts only). For your guarantee 

to be valid, your shower must be installed by a competent 

person, in accordance with the instruction manual. 

Bristan will repair or replace (at our option), free of 

charge, any faulty components during the guarantee 

period, provided it has been maintained and operated 

in accordance with our instructions, and has not been 

misused or damaged.

Modification or repair of this product by person(s) not 

authorised by Bristan will invalidate this guarantee.

This guarantee does not affect your statutory rights.

Service Policy 

Replacement Parts Policy

Important: 

In the event of product or component malfunction,  

DO NOT tamper with or remove the product from site. 

Telephone the Customer Services Department and be 

prepared with the date of purchase, model number and  

a clear description of the complaint.

Our service staff are fully qualified to advise on correct 

installation procedures and will be able to diagnose 

whether the fault will require a replacement part or a visit 

from a Bristan engineer.

If required, a service call will be booked and either yourself 

or an appointed representative (who should be a person of 

18 years or over) must be present during the visit. 

All site visits to product within the guarantee period will 

be carried out free of any parts or labour charges provided 

the conditions of the guarantee have been adhered to (the 

second year guarantee is parts only).

All site visits to product out of guarantee will be subject to 

charges for parts and labour. Charges will also be levied on 

cancelled appointments, unless advised to Bristan at least 

24 hours in advance of the agreed date and time.

Should a product be discontinued, spare parts stocks 

will be maintained, but in the event of a part becoming 

unavailable Bristan reserve the right to supply a substitute 

of equal quality.

For spare parts please contact Customer Services or via 

the Bristan website. 

Opening times: Please refer to the Bristan website.

Customer Service: 

Tel: 0844 7016273 • Fax: 0844 7016275
E-mail: [email protected]

Summary of Contents for Thermostatic Power Shower 1000

Page 1: ...ase keep this booklet for future reference Installer when you have read these instructions please ensure you leave them with the user Installation Instructions and User Guide Thermostatic Power Shower 1000 ...

Page 2: ...g your shower 7 Fitting the riser rail 9 Commissioning testing the system 10 Operating the shower 11 Adjusting the showerhead 11 Cleaning maintenance 11 Troubleshooting 12 Spare parts 13 Guarantee 14 Service policy 14 Contents Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors ...

Page 3: ...g it smothering it on your hand or any other part of your body or foreign object Do not operate the shower if the water stops flowing during use or if the water is leaking from the shower unit itself General Safety Always switch off the power at the consumer unit and remove the correct circuit fuse before making any electrical connections or if you have to remove the cover of an installed unit The...

Page 4: ... and control knob already in place These have to be removed to install the shower Please follow the procedure below Pull off control knob 1 Remove all three fixing screws 2 The cover can now be slowly removed care should be taken not to strain wiring which is attached to the front cover This procedure can be reversed to replace the front cover and control knob after installation to the wall Need h...

Page 5: ...rrent I E E regulations As the colours of the wires in the cable not supplied used to connect to this appliance may not correspond with the coloured markings identifying the terminals in your switch please follow the procedure below Please use the cable entry point provided Failure to comply will eliminate any BEAB approval Procedure The wire which is coloured Blue or Black must be connected to th...

Page 6: ...ing valves must be fitted on hot and cold supply pipes Do not position unit in areas subjected to freezing conditions The temperature of your stored water must not exceed 65 C A stored water temperature of 60 C is considered sufficient to meet all normal requirements in line with the British Standard 6700 Warning All connecting pipe work should be earthed Procedure Plumbing Connections Isolate mai...

Page 7: ...ust be roughened or removed to ensure that the push fit fittings in the supply retain the pipe in position The inlet elbows supplied are of a standard length in some cases these will need to be shortened for correct installation Flush out the supply pipes to ensure that no debris enters the unit Cut the inlet elbows to the required length Locate the inlet elbows into the mixer valve inlets by push...

Page 8: ...llow Green to the terminal marked E Secure into position with the cable clamp and tighten the two fixing screws Do not fit the front cover at this stage refer to the commissioning procedure Note If the electrical supply cable is concealed in the wall ensure that it avoids the unit s fixing points so that fixing screws do not pierce the cable HOT COLD Need help Give us a call on 0844 701 6273 and s...

Page 9: ...ed fixing position using a 6mm drill to a depth of 35mm push the plugs 4 supplied into the hole and loosely fix the rail end using the screw supplied 5 checking that the rail is hanging vertically using the spirit level incorporated into the top end of the rail The bubble should be exactly between the two lines on the spirit level body Mark the position for the lower fixing screw move the rail to ...

Page 10: ...he stop start button on the front cover to operate the shower which will work as a power shower It is intended that the temperature knob aligned to the 12 o clock position you should get a comfortable shower temperature If however the shower is too hot or cold remove the control knob and adjust the brass spindle anti clockwise to increase the temperature clockwise to decrease When the desired show...

Page 11: ...g liquids powders or specified scratch cleaners on any surface finishes In order to avoid surface wear or chemical attack on any of your shower fittings when cleaning always use a damp cloth For persistent stains or marks you may use domestic liquid or soap Handset The Handset has three spray modes 1 Spray 2 Massage 3 Combination To select the desired showering mode grip the bezel of the handset a...

Page 12: ... is flowing No electricity supply to unit Check all fuses and electrical supply Pump operates but no water is flowing No water supply to unit Check isolating valves are turned on Check cold water storage tank has not run dry Poor performance Restrictions in water supply Check both hot and cold isolating valves are fully open Pump may have overheated Allow unit to cool and retry Unit may be incorre...

Page 13: ...ve assembly 1 08 SP 087 0211 Purge shower rocker switch 1 09 SP 087 0127 Pipe connection 1 10 SP 087 0110 Pump unit 1 11 SP 087 0068 Pipe cover 1 12 SP 086 0061 Long inlet elbow 2 13 SP 087 0035 Motor cover 1 14 SP 280 0024 Rail end cap 1 15 SP 280 0100 Spirit rail and slider assembly 1 16 SP 280 0033 Soap dish 1 17 SP 285 0820 Hose 1 18 SP 168 0204 Handshower 1 HOT COLD Need help Give us a call o...

Page 14: ...maintained and operated in accordance with our instructions and has not been misused or damaged Modification or repair of this product by person s not authorised by Bristan will invalidate this guarantee This guarantee does not affect your statutory rights Service Policy Replacement Parts Policy Important In the event of product or component malfunction DO NOT tamper with or remove the product fro...

Page 15: ...15 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors ...

Page 16: ...Bristan Group Ltd Birch Coppice Business Park Dordon Tamworth Staffordshire B78 1SG Web www bristan com Email enquire bristan com A Masco Company Issue POW SHX 1000 D2 Part Number 131 723 ...

Reviews: