This fitting needs to be installed in accordance with the following Installation Requirements 
and Notes (IRN) to ensure they meet the requirements of the Water Supply (Water Fittings) 
Regulations 1999 and the Scottish Byelaws 2004. For further details contact your Local Water 
Authority.

For

For

For

For backflow protection in premises or installations up to fluid category 5. 

backflow protection in premises or installations up to fluid category 5. 

backflow protection in premises or installations up to fluid category 5. 

backflow protection in premises or installations up to fluid category 5. 

The vertical distance of the outlet above the spill-over level shall be not less than 20  mm or 
twice the diameter of the inlet pipe to the fitting, whichever is the greater. If the fitting cannot 
be installed as indicated it shall be installed:-

a)  With a backflow prevention arrangement suitable for the Fluid Category or
b)  So that it draws water by gravity only from a cistern, cylinder or tank having a   

permanently open vent pipe, the vertical distance between the point at which the pipe 
or pipes supply water to the fittings is or are connected to the supply and the spill-
over level of any fixed appliances is not less than the dimensions stated above, and the 
vent pipe or pipes supply(ies) no other fittings (other than a draining tap) at a lower 

level.

It is essential that all pipe work is flushed through to remove debris and swarf that could 
otherwise damage the fitting. Once the pipe work has been flushed through, turn off the water 
supply at the stop valve.

Important:

Important:

Important:

Important: Independent stop valves complying with the current water regulations should be 
fitted as a means of isolating both water supplies to the fitting for servicing and/or 
maintenance work.

05

General Specifications

General Specifications

General Specifications

General Specifications

Operating pressure range (bar)

Min

Max

1.0

8.0 

Maximum static pressure – 10.0 bar

NOTE:

NOTE:

NOTE:

NOTE:---- Nominally equal (balanced) inlet supply pressures are recommended for optimum 
Performance of mixer taps.

BS 6700 recommends the temperature of stored water should never exceed 65°C. A stored water 
temperature of 60°C is considered sufficient to meet all nominal requirements and will minimise 
the build up of lime scale in hard water areas.

Summary of Contents for TG SNK C

Page 1: ...ence and request of replacement parts Please keep these instructions for future reference and request of replacement parts Installation Instructions User Guide Installation Instructions User Guide Installation Instructions User Guide Installation Instructions User Guide Target Monobloc Kitchen Mixer Chrome Target Monobloc Kitchen Mixer Chrome Target Monobloc Kitchen Mixer Chrome Target Monobloc Ki...

Page 2: ...ting instructions have been created to give you all of the information you need and if you need any further help please do not hesitate to give us a call on 0844 701 6273 Important Safety Information 03 Dimensions 04 General Specifications 05 Installation Requirements 05 Installation 06 07 Operation 08 Maintenance 08 Troubleshooting 09 Guarantee 10 Installation Notes 11 Contents Contents Contents ...

Page 3: ...m the could be a criminal offence to use this tap with a mains water supply drawn directly from the could be a criminal offence to use this tap with a mains water supply drawn directly from the could be a criminal offence to use this tap with a mains water supply drawn directly from the supply pipe supply pipe supply pipe supply pipe The supply pipe is the one which brings the water supply into yo...

Page 4: ...Dimensions Dimensions Dimensions Dimensions 04 BRISTAN 350 200 I ___ I _ _ 45 lt tZ ZT r LI 15 D 485 138 ...

Page 5: ...pen vent pipe the vertical distance between the point at which the pipe or pipes supply water to the fittings is or are connected to the supply and the spill over level of any fixed appliances is not less than the dimensions stated above and the vent pipe or pipes supply ies no other fittings other than a draining tap at a lower level It is essential that all pipe work is flushed through to remove...

Page 6: ...9 35mm Flat Cartridge 10 Cartridge Retaining Nut 11 Shroud 12 Handle Assembly including Cap Grub Screw 13 Copper Tails Pair 14 Reinforcing Plate 15 Hose Weight 16 Plinth Washer 17 Fixing Kit 18 Flexible Tails Pair 19 Check Valves Pair 20 White Protective Tube 21 Black Protective Tube Not Shown 20 12 5 Parts pre Parts pre Parts pre Parts pre assembled in box as part of tap body assembled in box as ...

Page 7: ...on to the hose and connect it to the threaded rod with the red washer sealing it 5 Fit the flexible tails to the copper tails and attach the check valves to both of the inlets Then connect the hot and cold supplies 6 Fully open the cartridge letting it run for a few minutes and check all joints for leaks Flexible Connecting Tails Flexible Connecting Tails Flexible Connecting Tails Flexible Connect...

Page 8: ...uld only last for a couple of seconds Constant dripping leaking when the tap is not in use Cartridge Valve not fully shutting off Service fitting and replace cartridge valve Refer to maintenance section on page 09 Fitting does not turn on Water supplies not turned on Check that the water supplies to the fitting are turned on Closed stop or service valve Open stop or service valve Troubleshooting T...

Page 9: ...ufacturing fault If the fault is found to be down to a manufacturing error the payment will be released and not charged This guarantee applies to products purchased within the United Kingdom or Republic of Ireland but does not apply to products used commercially The guarantee is only available to original purchasers who have proof of purchase The installation must allow ready access to all product...

Page 10: ... Note Note Note Note Never use abrasive detergents or disinfectants or those containing alcohol hydrochloric acid or phosphoric acid If the fitting begins to drip 1 Isolate both water supplies 2 Remove cap 16 and remove grub screw 15 below with a 2 5mm hexagonal key 3 Remove the handle 14 shroud 13 and brass retaining nut 12 and pull out the cartridge 11 complete with seal 4 Clean or replace cartr...

Page 11: ...11 Notes Notes Notes Notes BRISTAN ...