1.
Identify all components and check for completeness, particularly
before commencing installation.
2.
Install the taps to the basin/bath. The backnut (9) and washer (8)
are used underneath to secure the taps to the surface of the
basin/bath, with the washer (8) and plinth (7) above.
3.
Connect the hot and cold water supplies.
4.
Turn on the water supplies. Open both outlets, letting the water
flow for a few minutes to check all joints and connections for leaks.
Pack Contents
Pack Contents
Pack Contents
Pack Contents
1. Cap
x2
6. Flow Straightener
x2
2. Grub Screw
x2
7. Plinth
x2
3. Handle
x2
8. Washer
x4
4. Valve
x2
9. Backnut
x2
5. Body
x2
1
9
8
7
6
5
4
3
2
Specification
Specification
Specification
Specification
Min.
Max.
Operating pressure range (bar)
0.2
7.0
Maximum static pressure – 10.0 bar
NOTE:- Nominally equal (balanced) inlet supply pressures are recommended for optimum performance.
Designed to comply with BS EN 200 for single taps/ combination taps and BS EN 817 for single lever mixers, for
water systems of type 1 and 2 general technical specifications and to be used within systems designed to BS 6700.
BS 6700 recommends the temperature of stored water should never exceed 65°C. A stored water temperature of
60°C is considered sufficient to meet all nominal requirements and will minimise the build up of lime scale in hard
water areas.
Installation
Installation
Installation
Installation
These fittings are suitable for use at all supply pressures. However for optimum use both the hot and cold
supplies should be reasonably balanced.
If the fitting is installed at low pressure (tank fed), then the minimum distance from the highest installed position
of the outlet to the underside of the cold tank should be at least 2 metres to ensure adequate performance.
These taps and mixers should be installed in compliance with the Water Regulations. Where the supplies are
unbalanced, i.e. Hot water from cylinder tank / cold from the mains, approved check valves must be fitted in the
supply pipes. For further details contact your Local Water Authority.