![Bristan MINI2 TS1203 CL C Installation Instructions And User Manual Download Page 22](http://html1.mh-extra.com/html/bristan/mini2-ts1203-cl-c/mini2-ts1203-cl-c_installation-instructions-and-user-manual_2813408022.webp)
Adjusting the Temperature
The shower valve has been factory set
with equal (balanced) hot and cold
water supply pressures with the hot
water supply at 65ºC.
If your operating conditions are
different from those above, the outlet
water temperature may differ from the
factory setting.
If required the shower valve can be re-
calibrated to suit your own temperature
requirements.
Set the temperature control lever to
maximum and check the temperature
of the water with a thermometer. If the
temperature is not correct, re-calibrate
the shower valve.
1. Turn the lever anti-clockwise to the
maximum flow / temperature position.
2. Remove the handle: remove the
plastic cap, loosen the grub screw
using the hexagonal key and carefully
pull the handle off.
3. Using the hexagonal key, turn the
temperature adjusting screw to alter
the temperature.
• Turn clockwise for a cooler
temperature
• Turn anti-clockwise for a warmer
temperature
Note: This will be the maximum
temperature setting, it is
recommended that the temperature is
set no higher than 43ºC.
4. Once the correct temperature is
achieved, re-attach the handle and
close the valve. Ensure the stop on the
lever is in the correct position
(vertically down), allowing the valve to
turn on anti-clockwise.
5. Tighten the grub screw to lock the
handle in place and push fit the
plastic cap.
Maintenance
cont.
Temperature
adjusting screw
Cooler
Warmer
22
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisors.