Inlet connector elbow (right side down or rear)

5

4
3

Inlet connector elbow (left side, up, down or rear)

Outlet connection 

5

3

4

 Warning:

 The outlet of the shower acts as a vent  

 

and must not be blocked, restricted or connected to  

 

any tap/closure device other than the handset    

 supplied.

Do not solder within 300mm of the shower unit or allow 

solder or flux to fall onto the casings. 

Important:

 An additional independent stop valve complying 

with the current water regulations must be fitted in the 

mains water supply as a means of isolating the supply to the 

unit for servicing and/or maintenance work.  

It is essential that all pipe work is flushed through to remove 

debris and swarf that could otherwise damage the unit. 

Once the pipe work has been flushed through, turn off the 

water supply at the stop valve.

Connect the mains water supply to the inlet port of the 

shower using 15mm copper pipe (BS EN1057) or 15mm 

plastic pipe (with insert).  

Do not

 use stainless steel pipe work. If using chrome plated 

pipe ensure that the first 25mm of plating is carefully 

removed to allow push-fit fitting to grip the inlet pipe.

Inlet Entry Options

The pipe work can enter the shower unit from 6 different 

positions.  

Bottom left, Bottom right, Top left, Rear left, Rear right or 

Rear left - using an elbow (as shown on page 11).

To top or bottom left positions

The shower unit should come supplied with the inlet 

connection set for a bottom left position. To change it to 

a top left position: swivel the inlet connector elbow from 

facing downward to facing upward. 

To bottom right position

Unfasten the screw (3) securing the inlet connector elbow 

clamp (4), remove the tab from the slot and keep until the 

inlet pipe is repositioned. Lift the outlet connection (5) up 

out of the way from its position at the bottom of the unit. 

Pull the inlet connector elbow towards you and over to the 

right hand side with the inlet entry point facing down. Refit 

the clamp tab (4) into the slot on the right, refasten the 

screw (3) and replace the outlet connection (5).

To rear entry positions

Swivel the inlet connector elbow to face a rear entry pipe 

connection.  

If the pipe work entry is from the rear,

 ensure that there is 

space left around the push-fit elbow for future servicing or 

alternatively access is possible from the rear. Bring the cold 

water pipe to the shower position and connect to the inlet 

elbow.

12

Need help?

 Give us a call on

 0330 026 6273

 and speak to one of our trained advisors.  

Plumbing Connections

Summary of Contents for Joy ThermoSafe JOYT385 W

Page 1: ...OYT385 MS JOYT395 W JOYT395 MS Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave them with the user Installation Instructions and Us...

Page 2: ...ns are for your guidance to a safe and successful installation which we recommend is carried out by a suitably qualified person and must conform with current I E E Wiring Regulations BS7671 and Buildi...

Page 3: ...roughly and retain for future use All products manufactured and supplied by Bristan are safe provided they are installed used correctly and receive regular maintenance in accordance with these instruc...

Page 4: ...t has been designed to be modified by the installer Fit only shower heads recommended by the manufacturer You must not fit a water saving handset whereby the flow of water can be restricted or turned...

Page 5: ...t the water within the water heater and the whole cycle will repeat itself until the temperature is manually reduced Warm Up Mode The light around the STOP START Button will flash as the water heats u...

Page 6: ...tom Right hand side Bottom Rear bottom Operating Pressures Minimum working pressure 0 07 MPa 0 7 bar Maximum working pressure 1 0 MPa 10 bar Static pressure range 0 1 0 MPa 0 10 bar Supply Requirement...

Page 7: ...must not be connected to a ring main spur power socket or lighting circuit If you don t have a spare fuse way or the rating at the main fuse box is below 80A you should seek advice from an electricia...

Page 8: ...derating factors On installation of the appliance the impedance measurement of the Neutral and Earth back to the supply source is to be less than 1 0 Ohms This is in line with the general installatio...

Page 9: ...e spill over level of the bath or shower tray or other fixed appliance If a showerhead can sit within a bath basin or shower tray you must fit a double check valve in the supply pipe work to prevent b...

Page 10: ...r Remove the template from the wall and drill the wall to suit the wall fixings to be used Tips A piece of insulation or masking tape positioned where holes are to be drilled and before marking out th...

Page 11: ...inlet entry Rear left inlet entry using a 15mm compression elbow not supplied where NO rear access is available Rear left inlet entry requiring rear access Rear right inlet entry requiring rear access...

Page 12: ...pipe work can enter the shower unit from 6 different positions Bottom left Bottom right Top left Rear left Rear right or Rear left using an elbow as shown on page 11 To top or bottom left positions Th...

Page 13: ...for water leaks at the shower inlet Once inspected turn off the water supply Pressure Relief Device PRD A pressure relief device is designed into this shower The pressure relief device provides prote...

Page 14: ...This appliance and all connecting metal pipe work must be earthed Ensure that an earth continuity conductor is securely and permanently connected to all exposed metal parts of other services and appl...

Page 15: ...e directed to the terminal connection block within the unit Note When feeding cable through bottom entry points remove highlighted grey tab on pipe blanking cover if using 6mm cable For 10mm cable rem...

Page 16: ...through conduit or in trunking or by being embedded in the wall in accordance with current I E E Regulations Warning Do not switch on power to the shower unit until the cover and the cable to connect...

Page 17: ...asin bath or shower during shower installation Drill the wall at the marked fixing position to suit the wall fixings to be used loosely fix the rail with the large hole on the side shown and wall brac...

Page 18: ...fully clockwise position to the fully anti clockwise position Repeat this procedure several times until a continuous flow of water with no air bubbles is obtained from the shower hose Once you are sa...

Page 19: ...to compensate for rises in temperature resulting in safe showering temperatures If the user adjusts either the Power Control or Temperature Control the shower will again wait for the user s new desire...

Page 20: ...isplay shows CL This is a performance Maintenance Indication that routine service cleaning is advisable to maintain showering performance Follow the instructions to Clean the Showerhead Clean the Inle...

Page 21: ...increases before using again Increase water flow rate by turning temperature control to cooler setting Error code E1 appears in temperature indicator display Outlet water temperature thermistor fault...

Page 22: ...used or damaged Modification or repair of this product by person s not authorised by Bristan will invalidate this guarantee This guarantee does not affect your statutory rights Service Policy Replacem...

Page 23: ...c O rings x3 1 11 131 406 S Inlet Elbow Ass Inlet Elbow x1 inc O ring x1 1 12 131 404 S Filter Ass Filter x1 inc O ring x1 1 13 131 402 S Swivel Inlet Pipe Ass Swivel Inlet Pipe x1 inc O ring x1 1 14...

Page 24: ...7 20 4 17 8 9 19 10 1 5 6 11 12 13 14 18 15 15 24 Need help Give us a call on 0330 026 6273 and speak to one of our trained advisors Spare Parts...

Page 25: ...r Rail Ass Riser Rail x1 Riser Rail End Caps x2 1 04 1625A0A Slider Handset Holder Slider Handset Holder x1 1 05 81M500601 103 101 Soap Dish Soap Dish x1 1 06 61000018 Handset White Handset x1 1 06 61...

Page 26: ...this space to add any notes you or your installer may have regarding the plumbing system installation of this product 26 Need help Give us a call on 0330 026 6273 and speak to one of our trained advi...

Page 27: ...this space to add any notes you or your installer may have regarding the plumbing system installation of this product 27 Need help Give us a call on 0330 026 6273 and speak to one of our trained advi...

Page 28: ...our products effective from the date of purchase to give you peace of mind To start your free guarantee simply scan the QR code and register your product Alternatively visit www bristan com register F...

Reviews: