Maintenance cont.
Maintenance cont.
Maintenance cont.
Maintenance cont.
We advise that your fitting is regularly
serviced in hard water areas to maintain
optimum performance (see map of Hard
Water Regions in the UK on page 17.
If your fitting begins to leak the following
should be carried out;
Isolate both hot and cold water supplies to
the tap by either:
•
Turning the water supply off at the mains
stopcock or
•
Turning off the isolation valves to the tap.
Cleaning the Valves
Cleaning the Valves
Cleaning the Valves
Cleaning the Valves –
––
– Basin Taps, Bath Tap, Bath Filler and Bath Shower Mixer
Basin Taps, Bath Tap, Bath Filler and Bath Shower Mixer
Basin Taps, Bath Tap, Bath Filler and Bath Shower Mixer
Basin Taps, Bath Tap, Bath Filler and Bath Shower Mixer
8. Turn on water supply and check for leaks.
11. Contact our helpline should if problem
persists.
Handle
Cap
Grub
Screw
Spline
Adapter
1. Remove the cap from the underside of the
lever to reveal the concealed grub screw.
2. Unscrew the grub screw and pull the
handle upwards from the valve & Spline
adapter.
3. Using a suitable spanner remove the valve
from the tap body.
4. Clean the valve and the seating inside the
tap body.
5. If necessary replace the valve.
Please visit www.bristan.com/sparesfinder in
order to find spare parts for this product.
6. Replace the valve into the tap body and
tighten fully using a suitable spanner.
7. Replace handle assembly.
Valve
Tap Body
13
Anti-Splash