This product has been designed to comply with BS EN 200 for combination
taps to be used within systems designed to BS 6700.
BS 6700 recommends the temperature of stored water should never exceed
65°C. A stored water temperature of 60°C is considered sufficient to meet all
normal requirements and will minimise the build up of lime scale in hard water
areas.
If installing this product on a low pressure (tank fed) system please see
specification table below to determine the minimum distance required from
underside of the cold water tank to the outlet.
These taps and mixers should be installed in compliance with the Water
Regulations. Where the supplies are unbalanced, i.e. Hot water from cylinder
tank/cold from the mains, approved check valves must be fitted in the supply
pipes.
For further details contact your Local Water Authority.
P r o d u c t
Code
Working
Pressures
Inlet
Minimum distance
from cold water
tank to outlet
(metres)
Min
Max
DSC 3HBAS C
0.2
5.0
15mm Compression
Threaded Tail
2
DSC 3HBF C
0.4
5.0
3/4" BSP Threaded Tail
4
DSC WMBAS
C
0.2
5.0
15mm Compression
Threaded Tail
2
DSC WMBF C
0.5
5.0
22mm Compression
Threaded Tail
5
DSC BS C
0.2
5.0
1/2" BSP Threaded Tail
2
Maximum static pressure: 10.0 bar
System Requirements:
Gravity fed hot & cold (Equal pressures)
Gravity fed hot & cold (Differential pressure, maximum ratio 5:1)
Unvented systems
Instantaneous water heater (Combination boiler)
Specifications
Need help?
Give us a call on
0330 026 6273
and speak to one of our trained advisors.