19
Recessed Installation - First Fix
3. Fit wall outlet
There are two methods of fixing the wall
outlet depending on the type of wall:
a: With rear access once wall finished
Remove the backnut from the wall outlet
(12). Insert the wall outlet through a 21-
24mm hole in the wall and secure with the
backnut.
Plumb in the wall outlet assembly to the
shower valve outlet.
b: Without rear access once wall finished
Fit a ‘wall plate elbow’ (not supplied)
within the wall cavity and plumb in from
the shower valve.
Once the wall has been finished, remove
the backnut from the wall outlet (12).
Note:
The backnut is not required.
Screw the wall outlet into the ‘wall-plate
elbow’ using a suitable thread sealant.
Note:
If required, any decorating should
be complete now before starting the
Second Fix (page 20).
Important note:
Please note the depth of
the cavity required to mount the recessed
shower valve. From the back face of the
valve to the front face of the tiling should
be between 68-77mm to ensure correct
fixing of the concealing plate.
Take care to protect the shower valve
whilst finishing the surround.
Backnut