24
Maintenance -
cont.
Adjusting the Temperature
The shower valve has been factory set
with equal (balanced) hot and cold water
supply pressures with the hot water
supply at 65˚C.
If your operating conditions are different
from those above, the outlet water
temperature may differ from the factory
setting.
If required the shower valve can be re-
calibrated to suit your own temperature
requirements.
Set the temperature control to 38˚C and
check the temperature of the water with
a thermometer. If the temperature is not
correct, re-calibrate the shower valve:
1.
Remove the temperature control cover,
undo the screw and carefully remove the
handle but
do not
remove the plastic stop.
2.
Turn the spline clockwise to decrease
the temperature and anti-clockwise to
increase the temperature. Check the
temperature and adjust until you achieve
the required temperature.
3.
Replace the handle ensuring ‘38’ is at
the top of the handle and the ‘stop pin’
inside the handle is up against the plastic
stop.
4.
To finish, reinsert the screw and
push on the cover (will only fit on in one
position).
Screw
Cover
38˚C at top
Handle
Plastic stop
(Do not remove)
Spline
Summary of Contents for AR2 SHXMTFF