Brinkmann SFC1520 Series Operating Instructions Manual Download Page 3

BRINKMANN-Cutter pumps SFC1520…3000

 

 

 
BE3185 

Edition

 11/2019 

Limit of Application (Table 1) 

 ATTENTION  

The pumps are to be operated within their design 

limits. 

Applications outside of these limits are not ap-

proved. The manufacturer is not responsible for any 

damages resulting from use of the pumps in such 

applications. 

 

2.3 

Technical data 

Type 

SFC 

 

   

 

 

WARNING

 

 

 

Risk of fire and explosion! 

   Pump may not be used in potentially explosive 

      environments.  

 

 

Mediums 

Coolants, 

cooling- and cutting-oils on 

request. 

 

Flashing point of the 

medium to be 

pumped 

≥ 150 °C 

 

Chip material 

 

Aluminium, steel, coloured 

steels 

max. chip to coolant ratio by 

weight: 1.5% 

 

Chip geometry 

Chip bundles to max. Ø 100 

mm 

 

Kinetic viscosity of 

the medium 

...45 mm

2

/s 

 

Temperature of me-

dium   

0 ... 80 °C 

 

Dry running 

Dry running causes in-

creased wear and should be 

avoided. 

During the test of the direc-

tion of rotation (< 30 s) per-

missible. 

 

Switching-on fre-

quency per hour 

 

The pump SFC should be 

operated in continual opera-

tion mode, 

not pulsed 

mode

 

Ambient tempera-

ture  

40 °C 

 

   

Set-up altitude  

1000 m 

 

   

 
 

Type 

Max. del. 
pressure 
bar / spec. 
weight 1 

Max. del. 
volume 
 
l/min 

Height

1)

  

 
 
H mm 

Depth of 
immersion

1)

   

 
h mm 

Weight  
 
 
kg 

Power  
50 / 60 Hz 
 
kW 

SFC1520  /  370 

 

/  500 

 

/  620 

2.8 

1200 

612 

  372 

  502 

  622 

  144 

  149 

  153 

7.5    8.6 

SFC1820  /  370 

 

/  500 

 

/  620 

3.6 

1200 

620 

  372 

  502 

  622 

  173 

  176 

  180 

11.0   12.6 

SFC2320  /  400 

 

/  530 

 

/  650  

4.4 

1200 

974 

 400 

  530 

 650 

  223 

  227 

  233 

18.5   21.3 

SFC3000  /  690 

 

/  940  

4.6 

2500 

1067 

 693 

  943 

  273 

  287 

 

 33.5 

1)  Dimensions in accordance with drawing 1. 

The motor is surface-cooled and compliant with 

DIN IEC 34 and EN 60034 (protection degree IP 55).

 

Summary of Contents for SFC1520 Series

Page 1: ...ion 11 2019 1 BRINKMANN Cutter pumps SFC1520 3000 Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 180 sales brinkm...

Page 2: ...ates a hazard ous situation which if not avoided could result in death or serious personal injury The signal word CAUTION indicates a hazardous situation which if not avoided could result in mi nor or...

Page 3: ...ic viscosity of the medium 45 mm2 s Temperature of me dium 0 80 C Dry running Dry running causes in creased wear and should be avoided During the test of the direc tion of rotation 30 s per missible S...

Page 4: ...the personnel 3 5 Safety instructions relevant for op eration If hot or cold machine components involve hazards they must be guarded against acci dental contact Guards for moving parts e g coupling m...

Page 5: ...age Store pump in dry and protected areas and protect it against penetration of for eign bodies Always store pump above the freezing point 5 Installation and Connection 5 1 Mechanical installation WAR...

Page 6: ...may enter the tank 5 2 Electric wiring WARNING Electric shock All service work must be carried out by quali fied service personnel Pump must be discon nected from the power source and all rotating pa...

Page 7: ...hed on Verify that there is no voltage at the termi nal board Open terminal box and disconnect the power leads Empty out the pump 7 Operation WARNING Risk of injury by uncontrolled start up of the pum...

Page 8: ...ar due to the return flow of chips and additional load on the bearings The SFC pump should be operated in continual operation mode not pulsed mode The pump should transport medium with out chips for 1...

Page 9: ...m repair pump Motor overheats High on off cycling frequency Wrong power supply voltage or cycles Insufficient cooling See above Power supply must correspond with name plate rating Check air flow at mo...

Page 10: ...2 22 Shaft nut 23 Compensation disk 24 Shaft seal 25 O ring 26 Shaft seal SFC1820 50 Pump body 51 Shaft with rotor 52 Shaft seal 53 Intake cover 54 Socket head cap screw with lock DIN 912 55 Washer 56...

Page 11: ...with lock DIN 912 55 Washer 56 Chip breaker 57 Bearing bush 58 Socket head cap screw with lock DIN 7984 59 Inlet cover for SFC2320 60 Socket head cap screw with lock DIN 912 for SFC2320 61 Bushing car...

Page 12: ...WARNING Risk of injury due to sharp edges on pump components i e impeller blades Wear safety gloves WARNING Risk of injury by discharging parts Do not under any circumstances remove the screws on the...

Page 13: ...ew connections Pump Installation Secure pump against fall ing over i e with use of safety straps Reconnect immersion pump as described in point 5 ATTENTION When putting the pump back into use make sur...

Page 14: ...EG die Schutz ziele der Niederspannungsrichtlinie 2014 35 EU eingehalten With respect to potential electrical hazards as stated in appendix No 1 5 1 of the machine guide lines 2006 42 EC all safety p...